M. M. Isa, M. Kadir, C. Gomes, N. Azis, M. Izadi, O. S. Alyozbaky
{"title":"Analysis on magnetic flux density and core loss for hexagonal and butt-lap core joint transformers","authors":"M. M. Isa, M. Kadir, C. Gomes, N. Azis, M. Izadi, O. S. Alyozbaky","doi":"10.1109/SPEC.2016.7846227","DOIUrl":null,"url":null,"abstract":"This paper presents the results of new hexagonal configuration at the T-joint of three-phase transformer core. The proposed model is compared with previous T-joint design, Butt-lap, which is widely used at present by many transformer manufacturers. The magnetic flux density distribution and core loss of a transformer rated 1000kVA are analyzed for the two types of T-joint design. The 3D simulation are carried out by using the ANSYS-Maxwell software. The results show that the magnetic flux density of the hexagonal shape T-joint is well distributed compared to that in the Butt-lap T-joint design. The core loss for the proposed model (hexagon) T-joint indicates a reduction of more than 11 % compared to the Butt-lap T-joint design.","PeriodicalId":403316,"journal":{"name":"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)","volume":"235 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 2nd Annual Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC.2016.7846227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This paper presents the results of new hexagonal configuration at the T-joint of three-phase transformer core. The proposed model is compared with previous T-joint design, Butt-lap, which is widely used at present by many transformer manufacturers. The magnetic flux density distribution and core loss of a transformer rated 1000kVA are analyzed for the two types of T-joint design. The 3D simulation are carried out by using the ANSYS-Maxwell software. The results show that the magnetic flux density of the hexagonal shape T-joint is well distributed compared to that in the Butt-lap T-joint design. The core loss for the proposed model (hexagon) T-joint indicates a reduction of more than 11 % compared to the Butt-lap T-joint design.