Time Synchronization Attack in Synchrophasors-based Dynamic Thermal Rating Assessment: Impact and Analysis

G. Coletta, Antonio Pepiciello, A. Vaccaro, D. Villacci, G. Giannuzzi
{"title":"Time Synchronization Attack in Synchrophasors-based Dynamic Thermal Rating Assessment: Impact and Analysis","authors":"G. Coletta, Antonio Pepiciello, A. Vaccaro, D. Villacci, G. Giannuzzi","doi":"10.23919/AEIT.2018.8577398","DOIUrl":null,"url":null,"abstract":"Wide-Area Monitoring Systems play a key role in ensuring reliability and security of modern electric power system operation. Phasor Measurement Units are the enabling technology for WAMS, since they provide synchronized measurements in spread points of the system characterized by higher data flow rate compared to traditional SCADA systems. An interesting application of WAMSs is the Dynamic Thermal Rating assessment of power lines, that allows fully exploit the benefits deriving by massive penetration of Renewable Power Generators by dynamically evaluating the interconnections’ transfer capabilities, reducing congestions in the system.Despite these benefits, these systems are vulnerable to Time Synchronization Attacks, since the majority of PMUs uses GPS signals as time reference for the synchronization procedure.In this paper the impact of TSAs on the reliability of DTR assessment will be discussed by analyzing the first results obtained on a realistic case study.","PeriodicalId":413577,"journal":{"name":"2018 AEIT International Annual Conference","volume":"150 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 AEIT International Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/AEIT.2018.8577398","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Wide-Area Monitoring Systems play a key role in ensuring reliability and security of modern electric power system operation. Phasor Measurement Units are the enabling technology for WAMS, since they provide synchronized measurements in spread points of the system characterized by higher data flow rate compared to traditional SCADA systems. An interesting application of WAMSs is the Dynamic Thermal Rating assessment of power lines, that allows fully exploit the benefits deriving by massive penetration of Renewable Power Generators by dynamically evaluating the interconnections’ transfer capabilities, reducing congestions in the system.Despite these benefits, these systems are vulnerable to Time Synchronization Attacks, since the majority of PMUs uses GPS signals as time reference for the synchronization procedure.In this paper the impact of TSAs on the reliability of DTR assessment will be discussed by analyzing the first results obtained on a realistic case study.
基于同步量的动态热评级评估中的时间同步攻击:影响与分析
广域监控系统在保证现代电力系统运行的可靠性和安全性方面起着关键作用。相量测量单元是WAMS的使能技术,因为与传统的SCADA系统相比,相量测量单元在系统的扩展点提供同步测量,具有更高的数据流速率。wams的一个有趣的应用是电力线的动态热评级评估,它允许通过动态评估互连的传输能力来充分利用可再生能源发电机大规模渗透所带来的好处,减少系统中的拥堵。尽管有这些优点,但这些系统容易受到时间同步攻击,因为大多数pmu使用GPS信号作为同步过程的时间参考。本文将通过分析一个实际案例的初步结果来讨论tsa对DTR评估可靠性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信