Power active filter installation effect in three-phase four-wire distribution network

G. G. Zemerov, N. A. Ilyina, O. V. Ilyina, E. I. Sokol, D. Tugay
{"title":"Power active filter installation effect in three-phase four-wire distribution network","authors":"G. G. Zemerov, N. A. Ilyina, O. V. Ilyina, E. I. Sokol, D. Tugay","doi":"10.1109/EDM.2009.5174023","DOIUrl":null,"url":null,"abstract":"An active filter control strategy that uses pqr instantaneous power concept has been proposed to compensate for the harmonic distortion, line neutral current and reactive power in three-phase four-wire systems. The effectiveness of the proposed control was proved in simulations using Matlab/Simulink model of the power-supply system with an active filter where the harmonic pollution, reactive power and imbalance caused by a highly distorting load have been drastically reduced.","PeriodicalId":262499,"journal":{"name":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","volume":"317 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference and Seminar on Micro/Nanotechnologies and Electron Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDM.2009.5174023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

An active filter control strategy that uses pqr instantaneous power concept has been proposed to compensate for the harmonic distortion, line neutral current and reactive power in three-phase four-wire systems. The effectiveness of the proposed control was proved in simulations using Matlab/Simulink model of the power-supply system with an active filter where the harmonic pollution, reactive power and imbalance caused by a highly distorting load have been drastically reduced.
电力有源滤波器在三相四线制配电网中的安装效果
提出了一种采用pqr瞬时功率概念的有源滤波器控制策略,以补偿三相四线制系统中的谐波失真、线路中性电流和无功功率。利用Matlab/Simulink模型对带有源滤波器的供电系统进行了仿真,验证了该控制方法的有效性,大大降低了高畸变负载引起的谐波污染、无功功率和不平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书