Overcurrent protection of pole top distribution transformers that have tank mounted lightning arresters

J. Lunsford
{"title":"Overcurrent protection of pole top distribution transformers that have tank mounted lightning arresters","authors":"J. Lunsford","doi":"10.1109/TDC.1996.547576","DOIUrl":null,"url":null,"abstract":"When protecting distribution transformers, most protection engineers in the utility industry have recognized the importance of placing arresters either on the transformer tank or under oil within the transformer tank. This method greatly reduces arrester lead length and the associated increase in discharge voltage thereby improving transformer failure rates. To obtain the shortest lead lengths possible, utilities have moved from arrester installations on the pole or cross arm to arresters mounted on the transformer tank. By moving the arrester on the tank (or under oil), the lead lengths are shortened as much as possible. Utility experience has proven that this method of arrester protection will decrease the number of transformer failures due to lightning. Another benefit of moving the arrester to the load side of the fuse is that the fuse can also protect the arrester.","PeriodicalId":105076,"journal":{"name":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1996 Transmission and Distribution Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.1996.547576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

When protecting distribution transformers, most protection engineers in the utility industry have recognized the importance of placing arresters either on the transformer tank or under oil within the transformer tank. This method greatly reduces arrester lead length and the associated increase in discharge voltage thereby improving transformer failure rates. To obtain the shortest lead lengths possible, utilities have moved from arrester installations on the pole or cross arm to arresters mounted on the transformer tank. By moving the arrester on the tank (or under oil), the lead lengths are shortened as much as possible. Utility experience has proven that this method of arrester protection will decrease the number of transformer failures due to lightning. Another benefit of moving the arrester to the load side of the fuse is that the fuse can also protect the arrester.
装有储罐式避雷器的极顶配电变压器过流保护
在保护配电变压器时,大多数公用事业行业的保护工程师已经认识到在变压器油箱上或变压器油箱内的油下放置避雷器的重要性。这种方法大大减少了避雷器引线长度和相关的放电电压增加,从而提高了变压器故障率。为了获得尽可能短的引线长度,公用事业公司已经从安装在电线杆或横臂上的避雷器转向安装在变压器箱上的避雷器。通过移动油箱上的避雷器(或在油下),引线长度尽可能缩短。实用经验证明,这种避雷器保护方法将减少因雷击引起的变压器故障数量。将避雷器移到保险丝的负载侧的另一个好处是,保险丝也可以保护避雷器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书