{"title":"Clinical value of two compounding techniques for IVUS Palpography","authors":"M. Danilouchkine, F. Mastik, A. V. D. van der Steen","doi":"10.1109/ULTSYM.2009.5441622","DOIUrl":null,"url":null,"abstract":"This study aims at the in-vivo assessment of two compounding techniques for IVUS Palpography. To increase the elastographic contrast-to-noise ratio, Doyley et. al. proposed a compounding scheme for IVUS Palpography [1]. The neighboring IVUS frames acquired at diastole are paired to compute the luminal strain profiles or partial palpograms. Subsequently, the obtained strain maps are averaged to form a final compounded strain profile for a given cross-section of a coronary artery. This first scheme is further referred to as the classical compounding. The second scheme explicitly takes into account that the measured strains are only partially available. It attempts at reconstructing the missing elasticity values by using the available strain information in its direct vicinity using the Normalized Convolution method. The improved partial strain profiles are subsequently averaged in the same manner as in classical compounding. This scheme was coined as reconstructive compounding. Eight in-vivo IVUS pullbacks were used for the comparative analysis. The percentage of valid strains was 28.6±13.7% for the scheme without compounding, 94.3±4.4% and 99.7 ± 0.2% for the classical and reconstructive methods, respectively. Implementation of the compounding schemes significantly boosts the diagnostic information coming out of IVUS Palpography with the reconstructive scheme being the best.","PeriodicalId":368182,"journal":{"name":"2009 IEEE International Ultrasonics Symposium","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2009.5441622","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study aims at the in-vivo assessment of two compounding techniques for IVUS Palpography. To increase the elastographic contrast-to-noise ratio, Doyley et. al. proposed a compounding scheme for IVUS Palpography [1]. The neighboring IVUS frames acquired at diastole are paired to compute the luminal strain profiles or partial palpograms. Subsequently, the obtained strain maps are averaged to form a final compounded strain profile for a given cross-section of a coronary artery. This first scheme is further referred to as the classical compounding. The second scheme explicitly takes into account that the measured strains are only partially available. It attempts at reconstructing the missing elasticity values by using the available strain information in its direct vicinity using the Normalized Convolution method. The improved partial strain profiles are subsequently averaged in the same manner as in classical compounding. This scheme was coined as reconstructive compounding. Eight in-vivo IVUS pullbacks were used for the comparative analysis. The percentage of valid strains was 28.6±13.7% for the scheme without compounding, 94.3±4.4% and 99.7 ± 0.2% for the classical and reconstructive methods, respectively. Implementation of the compounding schemes significantly boosts the diagnostic information coming out of IVUS Palpography with the reconstructive scheme being the best.
两种复合技术在静脉静脉心动图中的临床应用价值
本研究旨在对两种静脉心动图复合技术进行体内评价。为了提高弹性成像的噪比,Doyley等人提出了IVUS Palpography的复合方案[1]。在舒张期获得的相邻IVUS帧配对以计算腔内应变分布图或部分心电图。随后,对得到的应变图进行平均,以形成给定冠状动脉截面的最终复合应变分布图。第一个方案进一步被称为经典复合。第二种方案明确考虑到测量的应变仅部分可用。它尝试使用归一化卷积方法利用其直接附近的可用应变信息来重建缺失的弹性值。改进后的局部应变曲线随后以与经典复合相同的方式平均。这个方案被称为重建复合。采用8例体内IVUS回拉进行比较分析。无复配方案的有效菌株检出率为28.6±13.7%,经典法和重建法分别为94.3±4.4%和99.7±0.2%。复合方案的实施显著提高了IVUS心动图的诊断信息,其中重建方案效果最好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信