{"title":"Design and experimental testing of robust MIMO controllers on TCV","authors":"M. Ariola, J. Lister, A. Pironti","doi":"10.1109/CCA.2000.897460","DOIUrl":null,"url":null,"abstract":"This paper describes the design and the experimental validation of a multivariable digital controller for a tokamak, the TCV. The design of the controller is based on a linearized, validated model of the plasma confined in the tokamak. The plant is MIMO and the various outputs are strongly coupled. Moreover the plant is open-loop unstable. The scope of the controller is to stabilize the plasma and to guarantee some closed-loop performance in terms of decoupling among the plant outputs. The proposed controller is composed of two nested loops: one is devoted to the vertical stabilization, the other, designed using the H/sup /spl infin// technique, guarantees the control of the plasma current and of the plasma shape. After massive simulations, this controller was successfully tested on the plant. The experimental results show a significant improvement of the performance with respect to those obtained with a PID MIMO controller, that was used before on the plant.","PeriodicalId":108537,"journal":{"name":"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2000. IEEE International Conference on Control Applications. Conference Proceedings (Cat. No.00CH37162)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCA.2000.897460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This paper describes the design and the experimental validation of a multivariable digital controller for a tokamak, the TCV. The design of the controller is based on a linearized, validated model of the plasma confined in the tokamak. The plant is MIMO and the various outputs are strongly coupled. Moreover the plant is open-loop unstable. The scope of the controller is to stabilize the plasma and to guarantee some closed-loop performance in terms of decoupling among the plant outputs. The proposed controller is composed of two nested loops: one is devoted to the vertical stabilization, the other, designed using the H/sup /spl infin// technique, guarantees the control of the plasma current and of the plasma shape. After massive simulations, this controller was successfully tested on the plant. The experimental results show a significant improvement of the performance with respect to those obtained with a PID MIMO controller, that was used before on the plant.