APC Systems Used in Broadband Carrier Systems for Video Signal Transmission

M. Kawashima, T. Higeta, K. Endo, G. Yazaki
{"title":"APC Systems Used in Broadband Carrier Systems for Video Signal Transmission","authors":"M. Kawashima, T. Higeta, K. Endo, G. Yazaki","doi":"10.1109/TCOM.1967.1089579","DOIUrl":null,"url":null,"abstract":"From the viewpoint of better utilization of synchronization information in suppressed carrier VSB (vestigial sideband) television signals, various carrier regeneration and phase tracking systems are examined. Two APC (automatic phase control) systems with improved utilization of synchronous information are discussed further with emphasis placed on their precision phase tracking and carrier regeneration characteristics. Test models of both systems have obtained a carrier phase accuracy of ± 0.5 degree, which permits color television transmission over a chain of long haul links. Practical utilization of the first system, which employs an approximateBSB(both sidebands) component is featured by the use of a variable parameter phase tracking control loop system which attains a stable, high sensitivity. To satisfy stability, sensitivity, and practical requirements, a second-order variable parameter astatic zero tracking system has been adopted. Response of the test equipment to a typical picture has been analyzed, and the theoretical results have been verified by experiment. If the sensitivity parameter is fixed, the first system becomes the phase tracking circuitry of the second system. This is a carrier reproducing system which uses time band filtering, sampling, and which must fully utilize trisynchronization (V- and H-synch and blanking) information to secure the start and continuance of sampling. Its carrier regeneration system features the use of a self-holding gate which synchronously gates by using the natural and horizontal synchronous periods and not regating for a certain fixed time period. The stationary and starting transient responses of this system are discussed and its reliable starting verified through experimentation. It has been found to be effective with an ECR (excess carrier ratio) of 0.5. A phase tracking method similar to that in the first system was used.","PeriodicalId":134522,"journal":{"name":"IEEE Transactions on Communication Technology","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1967-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Communication Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TCOM.1967.1089579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

From the viewpoint of better utilization of synchronization information in suppressed carrier VSB (vestigial sideband) television signals, various carrier regeneration and phase tracking systems are examined. Two APC (automatic phase control) systems with improved utilization of synchronous information are discussed further with emphasis placed on their precision phase tracking and carrier regeneration characteristics. Test models of both systems have obtained a carrier phase accuracy of ± 0.5 degree, which permits color television transmission over a chain of long haul links. Practical utilization of the first system, which employs an approximateBSB(both sidebands) component is featured by the use of a variable parameter phase tracking control loop system which attains a stable, high sensitivity. To satisfy stability, sensitivity, and practical requirements, a second-order variable parameter astatic zero tracking system has been adopted. Response of the test equipment to a typical picture has been analyzed, and the theoretical results have been verified by experiment. If the sensitivity parameter is fixed, the first system becomes the phase tracking circuitry of the second system. This is a carrier reproducing system which uses time band filtering, sampling, and which must fully utilize trisynchronization (V- and H-synch and blanking) information to secure the start and continuance of sampling. Its carrier regeneration system features the use of a self-holding gate which synchronously gates by using the natural and horizontal synchronous periods and not regating for a certain fixed time period. The stationary and starting transient responses of this system are discussed and its reliable starting verified through experimentation. It has been found to be effective with an ECR (excess carrier ratio) of 0.5. A phase tracking method similar to that in the first system was used.
APC系统在宽带载波系统中用于视频信号传输
从抑制载波残留边带电视信号中更好地利用同步信息的角度出发,研究了各种载波再生和相位跟踪系统。进一步讨论了两种提高同步信息利用率的自动相位控制系统,重点讨论了它们的精确相位跟踪和载波再生特性。两种系统的测试模型都获得了±0.5度的载波相位精度,这使得彩色电视可以通过一链长途链路传输。第一个系统的实际应用采用了一个近似的bsb(两侧带)组件,其特点是使用了一个可变参数相位跟踪控制回路系统,该系统达到了稳定、高灵敏度。为了满足稳定性、灵敏度和实际要求,采用了二阶变参数无迹零跟踪系统。分析了测试设备对典型图像的响应,并通过实验验证了理论结果。如果灵敏度参数固定,则第一系统成为第二系统的相位跟踪电路。这是一种载波再现系统,它采用时间带滤波和采样,必须充分利用三同步(V-和h -同步和消隐)信息来保证采样的开始和继续。其载流子再生系统的特点是采用自保持门,利用自然同步周期和水平同步周期同步闸门,在一定的固定时间段内不调整。讨论了该系统的稳态和启动瞬态响应,并通过实验验证了该系统的可靠启动。研究发现,当ECR(过量载流子比)为0.5时,它是有效的。采用了与第一个系统相似的相位跟踪方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信