Hybrid contact lens capable of intraocular pressure monitoring in noninvasive way

V. Laukhin, V. Lebedev, E. Laukhina, Raúl Martín, J. Pastor, Rosa Villa, J. Aguiló, C. Rovira, J. Veciana
{"title":"Hybrid contact lens capable of intraocular pressure monitoring in noninvasive way","authors":"V. Laukhin, V. Lebedev, E. Laukhina, Raúl Martín, J. Pastor, Rosa Villa, J. Aguiló, C. Rovira, J. Veciana","doi":"10.1109/TRANSDUCERS.2013.6627156","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is the development of devices for monitoring the intraocular pressure (IOP) variations in a non-invasive way. The importance of the problem is caused by the need of a glaucoma diagnostic by control of the IOP in patients. It has been shown [1] that monitoring of the IOP variations over 24 h may change the glaucoma management of patients. Here we present a new prototype of an IOP sensing device based on a commercial hybrid contact lens (HCL) that provides a greater comfort for patients. Although the HCL was equipped with the same sensing BL film as in [2], in the sensing lens fabrication, a new design approach has been used. This approach allowed the use of different parts of the same BL film gauge as the pressure sensor and temperature effect compensator.","PeriodicalId":202479,"journal":{"name":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2013.6627156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The purpose of this paper is the development of devices for monitoring the intraocular pressure (IOP) variations in a non-invasive way. The importance of the problem is caused by the need of a glaucoma diagnostic by control of the IOP in patients. It has been shown [1] that monitoring of the IOP variations over 24 h may change the glaucoma management of patients. Here we present a new prototype of an IOP sensing device based on a commercial hybrid contact lens (HCL) that provides a greater comfort for patients. Although the HCL was equipped with the same sensing BL film as in [2], in the sensing lens fabrication, a new design approach has been used. This approach allowed the use of different parts of the same BL film gauge as the pressure sensor and temperature effect compensator.
能无创监测眼压的混合型隐形眼镜
本文的目的是开发一种无创方式监测眼压(IOP)变化的设备。这个问题的重要性是由于需要通过控制患者的眼压来诊断青光眼。已有研究表明[1],监测24小时内IOP的变化可能会改变青光眼患者的治疗。在这里,我们提出了一种基于商用混合隐形眼镜(HCL)的IOP传感装置的新原型,为患者提供了更大的舒适度。虽然HCL配备了与[2]相同的感应BL膜,但在感应透镜的制造中,采用了新的设计方法。这种方法允许使用同一BL薄膜计的不同部分作为压力传感器和温度效应补偿器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信