V. Laukhin, V. Lebedev, E. Laukhina, Raúl Martín, J. Pastor, Rosa Villa, J. Aguiló, C. Rovira, J. Veciana
{"title":"Hybrid contact lens capable of intraocular pressure monitoring in noninvasive way","authors":"V. Laukhin, V. Lebedev, E. Laukhina, Raúl Martín, J. Pastor, Rosa Villa, J. Aguiló, C. Rovira, J. Veciana","doi":"10.1109/TRANSDUCERS.2013.6627156","DOIUrl":null,"url":null,"abstract":"The purpose of this paper is the development of devices for monitoring the intraocular pressure (IOP) variations in a non-invasive way. The importance of the problem is caused by the need of a glaucoma diagnostic by control of the IOP in patients. It has been shown [1] that monitoring of the IOP variations over 24 h may change the glaucoma management of patients. Here we present a new prototype of an IOP sensing device based on a commercial hybrid contact lens (HCL) that provides a greater comfort for patients. Although the HCL was equipped with the same sensing BL film as in [2], in the sensing lens fabrication, a new design approach has been used. This approach allowed the use of different parts of the same BL film gauge as the pressure sensor and temperature effect compensator.","PeriodicalId":202479,"journal":{"name":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2013.6627156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The purpose of this paper is the development of devices for monitoring the intraocular pressure (IOP) variations in a non-invasive way. The importance of the problem is caused by the need of a glaucoma diagnostic by control of the IOP in patients. It has been shown [1] that monitoring of the IOP variations over 24 h may change the glaucoma management of patients. Here we present a new prototype of an IOP sensing device based on a commercial hybrid contact lens (HCL) that provides a greater comfort for patients. Although the HCL was equipped with the same sensing BL film as in [2], in the sensing lens fabrication, a new design approach has been used. This approach allowed the use of different parts of the same BL film gauge as the pressure sensor and temperature effect compensator.