Soft Pipes Cause Reliability Problem in Bipolar Integrated Circuits

J. Casey, J. Lee, D. Redman, Don Zinmner
{"title":"Soft Pipes Cause Reliability Problem in Bipolar Integrated Circuits","authors":"J. Casey, J. Lee, D. Redman, Don Zinmner","doi":"10.1109/IRPS.1983.361983","DOIUrl":null,"url":null,"abstract":"An investigation of yield-limiting bipolar emitter-collector shorts (commonly called \"pipes\") uncovered a \"soft\" pipe reliability problem. For us the major crystal defects causing pipes can be detected by Wright etching test wafers after epitaxial growth. The electrical effects of pipes become apparent during in-process probing and DC testing. Test patterns give a defect density figure which correlates with the corresponding etched wafer defect densities. Wafers which were below an appropriate defect level were shipped. Subsequent AC testing on a product line showed previously undetected, or \"soft\", pipes caused circuit timing errors and line returns from the customer. Both types of pipes were determined to be the result of secondary implantation of Carbon atoms arising from an ultrathin layer of vacuum pump oil. The Carbon atoms were knocked through the preimplant oxide during an Arsenic buried-layer implant step. Both types of pipes were eliminated by modifying the vacuum system on the implanter.","PeriodicalId":334813,"journal":{"name":"21st International Reliability Physics Symposium","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"21st International Reliability Physics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRPS.1983.361983","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An investigation of yield-limiting bipolar emitter-collector shorts (commonly called "pipes") uncovered a "soft" pipe reliability problem. For us the major crystal defects causing pipes can be detected by Wright etching test wafers after epitaxial growth. The electrical effects of pipes become apparent during in-process probing and DC testing. Test patterns give a defect density figure which correlates with the corresponding etched wafer defect densities. Wafers which were below an appropriate defect level were shipped. Subsequent AC testing on a product line showed previously undetected, or "soft", pipes caused circuit timing errors and line returns from the customer. Both types of pipes were determined to be the result of secondary implantation of Carbon atoms arising from an ultrathin layer of vacuum pump oil. The Carbon atoms were knocked through the preimplant oxide during an Arsenic buried-layer implant step. Both types of pipes were eliminated by modifying the vacuum system on the implanter.
软管道导致双极集成电路可靠性问题
对产量受限的双极集电极短路(通常称为“管道”)的研究揭示了一个“软”管道可靠性问题。对于我们来说,外延生长后的Wright蚀刻测试晶片可以检测出导致管道的主要晶体缺陷。管道的电效应在过程探测和直流测试中变得明显。测试图给出与相应蚀刻晶圆缺陷密度相关的缺陷密度图。低于适当缺陷水平的晶圆被装运。随后对产品线进行的交流测试显示,以前未检测到的或“软”管道导致电路定时错误和客户退货。这两种管子都是由真空泵油的超薄层中产生的碳原子二次注入的结果。在砷埋层植入步骤中,碳原子被击穿了预植入氧化物。这两种类型的管道都是通过修改真空系统的种植。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信