{"title":"Power losses reduction analysis in Mae sariang microgrid system","authors":"Jetsada Kantiyawong, S. Premrudeepreechacharn","doi":"10.1109/ECTICON.2017.8096217","DOIUrl":null,"url":null,"abstract":"This paper presents research power losses analysis in Mae Sariang microgrid system (MGs) by installing distribution generators (DGs). The studied case is located in Mae Sariang district, Mae Hong Son province which is a remote area. The main grid cannot supply sufficient active power to high consumption load in the system because there are high power losses occur in 22 kV transmission lines. This paper solves this problem with appropriated DGs selecting. There are 4 types of DGs such as diesel generator, solar system, hydro generator and battery storage in Mae Sariang MGs. This paper finds which type and number of DGs will supply minimum power losses while the system is in the grid-connected mode or island mode. System analysis used the DigSILENT Power Factory software. Our research was carried out in the 22kV distribution system of the Provincial Electricity Authority of Thailand (PEA).","PeriodicalId":273911,"journal":{"name":"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2017.8096217","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents research power losses analysis in Mae Sariang microgrid system (MGs) by installing distribution generators (DGs). The studied case is located in Mae Sariang district, Mae Hong Son province which is a remote area. The main grid cannot supply sufficient active power to high consumption load in the system because there are high power losses occur in 22 kV transmission lines. This paper solves this problem with appropriated DGs selecting. There are 4 types of DGs such as diesel generator, solar system, hydro generator and battery storage in Mae Sariang MGs. This paper finds which type and number of DGs will supply minimum power losses while the system is in the grid-connected mode or island mode. System analysis used the DigSILENT Power Factory software. Our research was carried out in the 22kV distribution system of the Provincial Electricity Authority of Thailand (PEA).
本文研究了安装配电发电机的梅萨良微电网系统的功率损耗分析。所研究的病例位于湄洪山省湄Sariang区,这是一个偏远地区。由于22kv输电线路存在较大的功率损耗,主电网无法为系统中的高耗负荷提供足够的有功功率。本文通过选择合适的dg来解决这一问题。有4种类型的dg,如柴油发电机,太阳能系统,水轮发电机和电池存储在Mae Sariang mg。本文研究了系统在并网模式和孤岛模式下,哪种类型和数量的dg能提供最小的功率损耗。系统分析使用DigSILENT Power Factory软件。我们的研究是在泰国省电力局(PEA)的22kV配电系统中进行的。