Comparative assessment of a new electronic apex locator and radiographic measurement of root length in primary teeth: An in-vitro study.

M. Hiremath, S. K. Srinath, B. Balan, Sushma H S
{"title":"Comparative assessment of a new electronic apex locator and radiographic measurement of root length in primary teeth: An in-vitro study.","authors":"M. Hiremath, S. K. Srinath, B. Balan, Sushma H S","doi":"10.26715/rjds.13_1_3","DOIUrl":null,"url":null,"abstract":"Background: The success of pulpectomy relies upon exact measurement of root length. Traditionally, radiographs were the main tools for measuring root length; however, they have several limitations. Hence, Electronic apex locators have become popular these days. Aim and objective: To assess the efficiency of Propex Pixi and traditional radiographic method in measuring the root length of single rooted primary teeth. Materials and Methods: Thirty extracted human single rooted primary teeth were selected randomly. In-vivo environment was simulated by inserting tooth sample in alginate and the root length was determined by using Propex Pixi. Secondly, the root length was determined by conventional radiographic method and finally the exact root length was measured by direct visual method. Statistical analysis: The obtained data was assessed using Student paired ‘t’ test, intra-class correlation coefficient and regression analysis. Results: The study showed no significant difference between Propex Pixi and radiographic method(p=0.280). Both the electronic and radiographic methods displayed a high equivalence and compliance R=0.947 and R=0.826 with the actual measurement. Conclusions: Propex Pixi was as effective as radiographic method in measuring the root length of primary teeth. However, regression analysis showed that Propex Pixi can anticipate the exact value with 94.3% accuracy and radiographic method with 67.2% accuracy.","PeriodicalId":155332,"journal":{"name":"RGUHS Journal of Dental Sciences","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RGUHS Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26715/rjds.13_1_3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The success of pulpectomy relies upon exact measurement of root length. Traditionally, radiographs were the main tools for measuring root length; however, they have several limitations. Hence, Electronic apex locators have become popular these days. Aim and objective: To assess the efficiency of Propex Pixi and traditional radiographic method in measuring the root length of single rooted primary teeth. Materials and Methods: Thirty extracted human single rooted primary teeth were selected randomly. In-vivo environment was simulated by inserting tooth sample in alginate and the root length was determined by using Propex Pixi. Secondly, the root length was determined by conventional radiographic method and finally the exact root length was measured by direct visual method. Statistical analysis: The obtained data was assessed using Student paired ‘t’ test, intra-class correlation coefficient and regression analysis. Results: The study showed no significant difference between Propex Pixi and radiographic method(p=0.280). Both the electronic and radiographic methods displayed a high equivalence and compliance R=0.947 and R=0.826 with the actual measurement. Conclusions: Propex Pixi was as effective as radiographic method in measuring the root length of primary teeth. However, regression analysis showed that Propex Pixi can anticipate the exact value with 94.3% accuracy and radiographic method with 67.2% accuracy.
一种新型电子根尖定位器与乳牙根长放射测量的比较评估:一项体外研究。
背景:牙髓切除的成功依赖于牙根长度的精确测量。传统上,x光片是测量根长度的主要工具;然而,它们有一些限制。因此,电子顶点定位器已成为流行的这些天。目的与目的:比较Propex Pixi与传统放射学测量单根乳牙根长的效果。材料与方法:随机抽取30颗拔除的人单根乳牙。将牙样插入藻酸盐中模拟体内环境,用Propex Pixi测定牙根长度。其次用常规放射照相法测定根长,最后用目测法测定根长。统计分析:采用学生配对t检验、班级内相关系数和回归分析对所得数据进行评估。结果:本研究显示Propex Pixi与x线摄影方法无显著差异(p=0.280)。电子法和射线法与实际测量值均具有较高的等效性和符合性(R=0.947和R=0.826)。结论:Propex Pixi测量乳牙根长与x线法测量效果相当。回归分析显示,Propex Pixi预测的准确率为94.3%,x线法预测的准确率为67.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信