Yuan Changzhou, L. Chun, Wang Qionglong, Zhang Wei-tang, Lin Sicong, Z. Xing
{"title":"Implementation of multi-sampling current control for grid-connected inverters using TI TMS320F28377x","authors":"Yuan Changzhou, L. Chun, Wang Qionglong, Zhang Wei-tang, Lin Sicong, Z. Xing","doi":"10.1109/YAC.2017.7967600","DOIUrl":null,"url":null,"abstract":"With the development of renewable energy sources, grid-connected inverters become more and more important in modern power system. Current control plays an important role in the grid-connected inverter control system. To deal with the resonance issues of the LCL filter in inverter, Firstly, inverter model and delay transfer function are established. based on it, multi-sampling technique is introduced proved to be a suitable solution to reduce the delay in traditional inverter control system. How to implement multi-sampling technique in inverter control with TI F28377x series MCU is discussed and a hotfix for F28377 crossing point detection of modulation and carrier wave is raised. Experimental results with output currents and resonance stability margin validate the implementation of multi-sampling current control for grid-connected inverters.","PeriodicalId":232358,"journal":{"name":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 32nd Youth Academic Annual Conference of Chinese Association of Automation (YAC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/YAC.2017.7967600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
With the development of renewable energy sources, grid-connected inverters become more and more important in modern power system. Current control plays an important role in the grid-connected inverter control system. To deal with the resonance issues of the LCL filter in inverter, Firstly, inverter model and delay transfer function are established. based on it, multi-sampling technique is introduced proved to be a suitable solution to reduce the delay in traditional inverter control system. How to implement multi-sampling technique in inverter control with TI F28377x series MCU is discussed and a hotfix for F28377 crossing point detection of modulation and carrier wave is raised. Experimental results with output currents and resonance stability margin validate the implementation of multi-sampling current control for grid-connected inverters.