M. Cevallos, J. Dickens, A. Neuber, M. Haustein, H. Krompholz
{"title":"Self electrical breakdown in biodegradable oil","authors":"M. Cevallos, J. Dickens, A. Neuber, M. Haustein, H. Krompholz","doi":"10.1109/PPC.2003.1277989","DOIUrl":null,"url":null,"abstract":"The fundamental breakdown physics of biodegradable oil is investigated with high-speed electrical and optical diagnostics with temporal resolution down to several 100 ps. The set up employs a cable discharge into a coaxial system with axial discharge and load line to simulate matched terminating impedance. A unique feed-through design creates no discontinuities in the system lines through the discharge chamber. The impedance of the system is matched at 50 ohms including a novel design for impedance matching transitions from discharge cable to coaxial system to load line allowing for a sub-nanosecond response. This paper presents results on self-breakdown with voltages of up to 60 kV. Self-breakdown is achieved by charging the discharge cable and load line to +/-30 kV respectively. Transmission line type current sensors and a capacitive voltage divider with fast amplifiers/attenuators are used in order to obtain a complete range of information from amplitudes of 0.1 mA to 1 kA with temporal resolutions of 300 ps. Optical measurements include high speed photography and shadowgraphy. Detailed optical diagnostics along with high-speed electrical diagnostics will address the mechanism initiating/assisting biodegradable oil volume breakdown.","PeriodicalId":143385,"journal":{"name":"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2003.1277989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
The fundamental breakdown physics of biodegradable oil is investigated with high-speed electrical and optical diagnostics with temporal resolution down to several 100 ps. The set up employs a cable discharge into a coaxial system with axial discharge and load line to simulate matched terminating impedance. A unique feed-through design creates no discontinuities in the system lines through the discharge chamber. The impedance of the system is matched at 50 ohms including a novel design for impedance matching transitions from discharge cable to coaxial system to load line allowing for a sub-nanosecond response. This paper presents results on self-breakdown with voltages of up to 60 kV. Self-breakdown is achieved by charging the discharge cable and load line to +/-30 kV respectively. Transmission line type current sensors and a capacitive voltage divider with fast amplifiers/attenuators are used in order to obtain a complete range of information from amplitudes of 0.1 mA to 1 kA with temporal resolutions of 300 ps. Optical measurements include high speed photography and shadowgraphy. Detailed optical diagnostics along with high-speed electrical diagnostics will address the mechanism initiating/assisting biodegradable oil volume breakdown.