EFEK VARIASI BEBAN PENDINGINAN TERHADAP COEFFICIENT OF PERFORMANCE (COP) MESIN PENDINGIN PADA BOX COOLER ALAT DISTILASI

Ahmad Akromul Huda, Karyanik Karyanik, Earlyna Sinthia Dewi
{"title":"EFEK VARIASI BEBAN PENDINGINAN TERHADAP COEFFICIENT OF PERFORMANCE (COP) MESIN PENDINGIN PADA BOX COOLER ALAT DISTILASI","authors":"Ahmad Akromul Huda, Karyanik Karyanik, Earlyna Sinthia Dewi","doi":"10.31764/jau.v8i2.5239","DOIUrl":null,"url":null,"abstract":"Refrigerator has been widely used by the community and can be found in almost every shop, office building and household. The application of refrigeration machines can also be developed in many other equipment and machines, one of which is in the distillation apparatus. Distillation is a method of separating two substances. A distillation machine using a cooling machine in the condenser will be very helpful, especially for distillation. This study aims to determine the effect of cooling on the performance of the cooling machine. Cooling engine performance coefficient of achievement (COP). Load variations are carried out by adjusting the boiler temperature using a thermostat. In this study, data on the temperature and pressure of the refrigerant flowing in the refrigeration system were taken at four points, namely before entering the compressor, before entering the capillary tube and before entering the evaporator . In this study also used four variations of the cooling load given to the box cooler of 110 °C, 125 °C, 140 °C, and 155 °C. Then the temperature and pressure data is processed to get the COP value every time from all variations of the cooling load. The results showed that the increaseing in the cooling load, the smaller the COP value of the cooling machine. In its effect on the length of time the COP value of each variation of the cooling load increases. The highest COP value in this study was obtained at a cooling load temperature of 110 ºC of 10.69 and the lowest was obtained at a temperature of 155 ºC of 9.38.","PeriodicalId":276781,"journal":{"name":"Jurnal Agrotek UMMat","volume":"390 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Agrotek UMMat","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31764/jau.v8i2.5239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Refrigerator has been widely used by the community and can be found in almost every shop, office building and household. The application of refrigeration machines can also be developed in many other equipment and machines, one of which is in the distillation apparatus. Distillation is a method of separating two substances. A distillation machine using a cooling machine in the condenser will be very helpful, especially for distillation. This study aims to determine the effect of cooling on the performance of the cooling machine. Cooling engine performance coefficient of achievement (COP). Load variations are carried out by adjusting the boiler temperature using a thermostat. In this study, data on the temperature and pressure of the refrigerant flowing in the refrigeration system were taken at four points, namely before entering the compressor, before entering the capillary tube and before entering the evaporator . In this study also used four variations of the cooling load given to the box cooler of 110 °C, 125 °C, 140 °C, and 155 °C. Then the temperature and pressure data is processed to get the COP value every time from all variations of the cooling load. The results showed that the increaseing in the cooling load, the smaller the COP value of the cooling machine. In its effect on the length of time the COP value of each variation of the cooling load increases. The highest COP value in this study was obtained at a cooling load temperature of 110 ºC of 10.69 and the lowest was obtained at a temperature of 155 ºC of 9.38.
冰箱已经被社会广泛使用,几乎在每一个商店、办公楼和家庭中都可以找到。制冷机的应用还可以在许多其他设备和机器中得到发展,其中之一是在蒸馏装置中。蒸馏是分离两种物质的方法。在冷凝器中使用冷却机的蒸馏机将非常有帮助,特别是对蒸馏。本研究旨在确定冷却对冷却机性能的影响。冷却发动机性能成就系数(COP)。负荷变化是通过使用恒温器调节锅炉温度来实现的。在本研究中,对制冷系统中流动的制冷剂在进入压缩机前、进入毛细管前和进入蒸发器前四个点的温度和压力进行数据采集。在这项研究中,还使用了四种不同的冷却负荷,分别为110°C、125°C、140°C和155°C。然后对温度和压力数据进行处理,得到各工况下的COP值。结果表明:冷负荷越大,制冷机COP值越小;在其对时间长度的影响中,各冷负荷变化的COP值均增大。本研究中,110℃冷负荷温度下COP值最高,为10.69;155℃冷负荷温度下COP值最低,为9.38。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信