{"title":"A novel technique for optimal PMU placement with effects on dynamic state estimation","authors":"R. Dubey","doi":"10.1109/CIEC.2016.7513825","DOIUrl":null,"url":null,"abstract":"In this paper a new priority based elimination technique (PBET) has been presented to obtain minimum number of phasor measurement unit (PMU) in power system network for full system observability and based on optimal PMU location state estimation (SE) has been done. Power system network should completely observable hence it's required to have all bus data in real time. It is not neither necessary to have PMUs at each buses in network nor economical. The proposed method is based on simple algorithm without having any cost function. Four steps procedure has been discussed in detailed for IEEE-14, IEEE-24 and IEEE-30 bus system and results are compared with other techniques. State estimation has been discussed for IEEE-14 bus system and normalized errors are obtained with optimally placed PMU and other configuration of PMU. Results show that PBET is compatible with other techniques of PMU placement.","PeriodicalId":443343,"journal":{"name":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Control, Instrumentation, Energy & Communication (CIEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIEC.2016.7513825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper a new priority based elimination technique (PBET) has been presented to obtain minimum number of phasor measurement unit (PMU) in power system network for full system observability and based on optimal PMU location state estimation (SE) has been done. Power system network should completely observable hence it's required to have all bus data in real time. It is not neither necessary to have PMUs at each buses in network nor economical. The proposed method is based on simple algorithm without having any cost function. Four steps procedure has been discussed in detailed for IEEE-14, IEEE-24 and IEEE-30 bus system and results are compared with other techniques. State estimation has been discussed for IEEE-14 bus system and normalized errors are obtained with optimally placed PMU and other configuration of PMU. Results show that PBET is compatible with other techniques of PMU placement.
一种影响动态估计的PMU最优放置方法
本文提出了一种新的基于优先级的消去技术(PBET),以获得电网中最优相量测量单元(PMU)的数量,实现了系统的完全可观测性,并基于最优PMU位置状态估计(SE)。电力系统网络应该是完全可观测的,因此要求所有母线的数据都是实时的。在网络的每条总线上都安装pmu既没有必要,也不经济。该方法基于简单的算法,不含任何代价函数。详细讨论了IEEE-14、IEEE-24和IEEE-30总线系统的四步程序,并与其他技术的结果进行了比较。讨论了IEEE-14总线系统的状态估计问题,并在PMU的最优位置和PMU的其他配置下得到归一化误差。结果表明,PBET与其他PMU放置技术是兼容的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信