Investigation of the relative sensitivity of control of impulse X-ray television systems

S. R. Mikhailov, N. V. Slobodian, D. Shilo
{"title":"Investigation of the relative sensitivity of control of impulse X-ray television systems","authors":"S. R. Mikhailov, N. V. Slobodian, D. Shilo","doi":"10.1109/ELNANO.2013.6552043","DOIUrl":null,"url":null,"abstract":"Method of calculating the relative sensitivity for X-ray television systems based on X-ray screens, CCD cameras and impulse x-ray devices was proposed. To visualize the images formed by the pulsed X-ray radiation, an adjustable duration of accumulation on the CCD camera was used. The relative sensitivity of the control is determined by the intersection of dependences of the luminance and threshold contrast on the size of the defect. The comparison of calculated and experimental values of the relative sensitivity of control is made in this paper.","PeriodicalId":443634,"journal":{"name":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2013.6552043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Method of calculating the relative sensitivity for X-ray television systems based on X-ray screens, CCD cameras and impulse x-ray devices was proposed. To visualize the images formed by the pulsed X-ray radiation, an adjustable duration of accumulation on the CCD camera was used. The relative sensitivity of the control is determined by the intersection of dependences of the luminance and threshold contrast on the size of the defect. The comparison of calculated and experimental values of the relative sensitivity of control is made in this paper.
脉冲x射线电视系统控制的相对灵敏度研究
提出了基于x射线屏、CCD相机和脉冲x射线装置的x射线电视系统相对灵敏度的计算方法。为了使脉冲x射线辐射形成的图像可视化,在CCD相机上使用了可调的积累时间。控制的相对灵敏度由亮度和阈值对比度对缺陷大小的依赖性的交集决定。本文对控制相对灵敏度的计算值与实验值进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信