Analyzing the Performance of Identical PV Modules in a Semi-Arid Region over a 2-year Period

A. Swart
{"title":"Analyzing the Performance of Identical PV Modules in a Semi-Arid Region over a 2-year Period","authors":"A. Swart","doi":"10.26803/myres.2018.08","DOIUrl":null,"url":null,"abstract":"It is assumed that similar PV modules are expected to perform equally well under the same atmospheric conditions, especially with regard to their rated output power. However, this is not always the case due to a number of factors, which include cell degradation overtime and cell manufacturing. It has been reported that PV modules within arrays need to be identical. This is required to have equal currents flow through the branches of an array in order to prevent power mismatches, hot spots and a lower overall output power. The purpose of this paper is to analyze the performance of three identical 10 W PV modules which were used over a 2-year period in a semi-arid region, in order to identify any anomalies. An experimental research design is employed where three identical 10 W PV modules were each connected to its own power loads that were to extract more than 90% of the rated power of the module over a 2-year period. A data logging circuit is included that provides power conditioning between the PV modules and an Arduino UNO board, which serves as the data logger. This logger relays the measured data to LabVIEW where the processing, display and recording is done. Two key anomalies that were identified relate to the abnormal degradation in output power of one of the modules and the abnormal improvement in output power when a newly manufactured module is introduced into the system.","PeriodicalId":269540,"journal":{"name":"2018 International Conference on Multidisciplinary Research","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Multidisciplinary Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26803/myres.2018.08","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

It is assumed that similar PV modules are expected to perform equally well under the same atmospheric conditions, especially with regard to their rated output power. However, this is not always the case due to a number of factors, which include cell degradation overtime and cell manufacturing. It has been reported that PV modules within arrays need to be identical. This is required to have equal currents flow through the branches of an array in order to prevent power mismatches, hot spots and a lower overall output power. The purpose of this paper is to analyze the performance of three identical 10 W PV modules which were used over a 2-year period in a semi-arid region, in order to identify any anomalies. An experimental research design is employed where three identical 10 W PV modules were each connected to its own power loads that were to extract more than 90% of the rated power of the module over a 2-year period. A data logging circuit is included that provides power conditioning between the PV modules and an Arduino UNO board, which serves as the data logger. This logger relays the measured data to LabVIEW where the processing, display and recording is done. Two key anomalies that were identified relate to the abnormal degradation in output power of one of the modules and the abnormal improvement in output power when a newly manufactured module is introduced into the system.
半干旱地区2年相同光伏组件性能分析
假设在相同的大气条件下,类似的光伏组件预期表现同样良好,特别是在其额定输出功率方面。然而,由于许多因素,包括细胞降解和细胞制造,情况并非总是如此。据报道,阵列内的光伏组件需要相同。这需要有相等的电流流过阵列的分支,以防止功率不匹配,热点和较低的总输出功率。本文的目的是分析三个相同的10瓦光伏组件的性能,这些组件在半干旱地区使用了2年,以确定任何异常。采用实验研究设计,其中三个相同的10w光伏模块每个连接到自己的功率负载,在2年的时间内提取超过90%的模块额定功率。数据记录电路提供PV模块和Arduino UNO板之间的电源调节,Arduino UNO板作为数据记录器。该记录仪将测量到的数据传送到LabVIEW中进行处理、显示和记录。确定的两个关键异常与其中一个模块的输出功率异常下降和新制造的模块引入系统时输出功率异常改善有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信