Comparison of Repeated Chemical and Microwave Disinfection on Dimensional Accuracy of Gypsum Casts

Mariya Khalid, M. A. Chughtai, S. Shaheed, Syed Nasir Shah
{"title":"Comparison of Repeated Chemical and Microwave Disinfection on Dimensional Accuracy of Gypsum Casts","authors":"Mariya Khalid, M. A. Chughtai, S. Shaheed, Syed Nasir Shah","doi":"10.25301/jpda.304.235","DOIUrl":null,"url":null,"abstract":"OBJECTIVE: The aim of this experimental study is to compare the dimensional accuracy of gypsum casts after repeated disinfection in microwave at 900 Watts, 2450 MHz (5 minutes) and immersion in 0.5% Sodium hypochlorite (10 minutes). Disinfecting casts is recommended to prevent cross infection but may cause dimensional changes. During fabrication of prosthesis, a cast may get contaminated several times so there is a need of repeated disinfection. METHODOLOGY: Sample size was 33 (11 in each group), calculated through WHO software for sample size determination by using standard deviation of 0.16 at 95% confidence interval and 80% power of study. Impressions in irreversible hydrocolloid were recorded of an acrylic cast fabricated for this study. The impressions were poured with die stone and were randomly divided into 3 groups; Group I: Microwave disinfection, Group II: Immersion disinfection in 0.5% Sodium hypochlorite, Group III: Control group. For Groups I and II, each cast was disinfected 7 times with 5 minutes interval between two disinfection cycles, after every cycle anteroposterior and mediolateral measurements were recorded using digital Vernier caliper (accuracy upto 0.01 mm). For group III, casts were rinsed with distilled water, dried in open air within temperature range of 28+/-2OC for 10 mins followed by anteroposterior and mediolateral measurements. This procedure was repeated seven times for each cast. RESULTS: Anteroposterior and Mediolateral differences of dimensional change between and within the Group A, B and C was calculated by One Way ANOVA. Inter/intra examiner reliability was taken into consideration at the time of study. Mean dimensional change in the casts were insignificant through six disinfecting cycles. However, in the seventh cycle, a significant difference (p=0.003) was observed in the anteroposterior dimension (0.03% dimensional change for Group A and 1.26 % for Group B whereas, in mediolateral dimension, dimensional change was 0.35% for Group A and 0.59% for Group B (p=0.004). Dimensional change of >0.5% was considered as the cutoff value for casts to be considered as dimensionally accurate. Casts disinfected through immersion disinfection did not produce dimensionally inaccurate casts in anteroposterior dimension after third cycle and in seventh cycle in mediolateral dimension. However, result is significant only in seventh cycle. Microwave disinfection produced dimensionally accurate casts throughout all cycles. CONCLUSION: Microwave disinfected casts remained dimensionally stable compared to immersion disinfection. KEYWORDS: Disinfection, microwave, immersion, dimensional stability, gypsum casts","PeriodicalId":191918,"journal":{"name":"Journal of the Pakistan Dental Association","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Pakistan Dental Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25301/jpda.304.235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

OBJECTIVE: The aim of this experimental study is to compare the dimensional accuracy of gypsum casts after repeated disinfection in microwave at 900 Watts, 2450 MHz (5 minutes) and immersion in 0.5% Sodium hypochlorite (10 minutes). Disinfecting casts is recommended to prevent cross infection but may cause dimensional changes. During fabrication of prosthesis, a cast may get contaminated several times so there is a need of repeated disinfection. METHODOLOGY: Sample size was 33 (11 in each group), calculated through WHO software for sample size determination by using standard deviation of 0.16 at 95% confidence interval and 80% power of study. Impressions in irreversible hydrocolloid were recorded of an acrylic cast fabricated for this study. The impressions were poured with die stone and were randomly divided into 3 groups; Group I: Microwave disinfection, Group II: Immersion disinfection in 0.5% Sodium hypochlorite, Group III: Control group. For Groups I and II, each cast was disinfected 7 times with 5 minutes interval between two disinfection cycles, after every cycle anteroposterior and mediolateral measurements were recorded using digital Vernier caliper (accuracy upto 0.01 mm). For group III, casts were rinsed with distilled water, dried in open air within temperature range of 28+/-2OC for 10 mins followed by anteroposterior and mediolateral measurements. This procedure was repeated seven times for each cast. RESULTS: Anteroposterior and Mediolateral differences of dimensional change between and within the Group A, B and C was calculated by One Way ANOVA. Inter/intra examiner reliability was taken into consideration at the time of study. Mean dimensional change in the casts were insignificant through six disinfecting cycles. However, in the seventh cycle, a significant difference (p=0.003) was observed in the anteroposterior dimension (0.03% dimensional change for Group A and 1.26 % for Group B whereas, in mediolateral dimension, dimensional change was 0.35% for Group A and 0.59% for Group B (p=0.004). Dimensional change of >0.5% was considered as the cutoff value for casts to be considered as dimensionally accurate. Casts disinfected through immersion disinfection did not produce dimensionally inaccurate casts in anteroposterior dimension after third cycle and in seventh cycle in mediolateral dimension. However, result is significant only in seventh cycle. Microwave disinfection produced dimensionally accurate casts throughout all cycles. CONCLUSION: Microwave disinfected casts remained dimensionally stable compared to immersion disinfection. KEYWORDS: Disinfection, microwave, immersion, dimensional stability, gypsum casts
重复化学消毒与微波消毒对石膏铸件尺寸精度的影响
目的:比较900瓦、2450 MHz(5分钟)微波反复消毒和0.5%次氯酸钠浸泡(10分钟)后石膏铸件的尺寸精度。建议对铸型进行消毒,以防止交叉感染,但可能导致尺寸变化。在假体制作过程中,石膏可能会被污染多次,因此需要反复消毒。方法:样本量为33例(每组11例),通过WHO软件计算,样本量确定采用95%置信区间0.16的标准差和80%的研究效力。在不可逆的水胶体中记录了为本研究制作的丙烯酸铸型的印模。用模石浇筑印模,随机分为3组;第一组:微波消毒,第二组:0.5%次氯酸钠浸泡消毒,第三组:对照组。ⅰ组和ⅱ组每个铸型消毒7次,两次消毒周期间隔5分钟,每次消毒周期后用数字游标卡尺记录正、中外侧测量值(精度可达0.01 mm)。对于第三组,用蒸馏水冲洗铸件,在28+/- 20℃的温度范围内露天干燥10分钟,然后进行前后和中外侧测量。每次铸型重复7次。结果:采用单因素方差分析(One Way ANOVA)计算A、B、C组间及组内正、中外侧尺寸变化差异。在研究时考虑了审查员之间/内部的可靠性。经过6次消毒循环,铸件的平均尺寸变化不显著。然而,在第7个周期中,在正侧维度观察到显著差异(p=0.003) (a组的尺寸变化为0.03%,B组的尺寸变化为1.26%),而在中侧维度,a组的尺寸变化为0.35%,B组的尺寸变化为0.59% (p=0.004)。尺寸变化大于0.5%被认为是铸件尺寸精确的截止值。浸没消毒后的铸件在第3循环前后和第7循环中均未产生尺寸不准确的铸件。然而,只有在第七个周期,结果才显著。微波消毒在所有循环中产生尺寸精确的铸件。结论:与浸泡消毒相比,微波消毒能保持铸件的尺寸稳定性。关键词:消毒、微波、浸泡、尺寸稳定性、石膏铸件
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信