{"title":"Method to protect lines of two cables from single phase-to-earth fault","authors":"A. Novozhilov, Zhanat B. Issabekov, T. Novozhilov","doi":"10.1109/ICIEAM.2016.7911418","DOIUrl":null,"url":null,"abstract":"The method of protection against single phase-to-earth fault of the electric line of two cables based on measurement of current difference of zero-sequence in cables of this line has been developed. For this purpose, a simple method of zero-sequence current simulation in line of two cables, based on the conversion of an electrical network scheme to the design scheme and use of the Electronics Workbench general-circuit simulation system is offered. The paper reveals dependences of these currents and their difference from the location of a point of single phase-to-earth fault and sizes of capacity concerning the earth of all lines of a network except for the studied two-cable and offers schemes for implementation of the protection organization on this method and defined zone of its action.","PeriodicalId":130940,"journal":{"name":"2016 2nd International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","volume":"215 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEAM.2016.7911418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The method of protection against single phase-to-earth fault of the electric line of two cables based on measurement of current difference of zero-sequence in cables of this line has been developed. For this purpose, a simple method of zero-sequence current simulation in line of two cables, based on the conversion of an electrical network scheme to the design scheme and use of the Electronics Workbench general-circuit simulation system is offered. The paper reveals dependences of these currents and their difference from the location of a point of single phase-to-earth fault and sizes of capacity concerning the earth of all lines of a network except for the studied two-cable and offers schemes for implementation of the protection organization on this method and defined zone of its action.