Nursing Technology in Vibration Perception Threshold Testing in Diabetic Peripheral Neuropathy Patients

Kharisma Pratama, Suriadi, Gusti Jhoni Putra, D. Setiawan, A. Djalil, Cau Kim Jiu, Usman, Tisa Gusmiah
{"title":"Nursing Technology in Vibration Perception Threshold Testing in Diabetic Peripheral Neuropathy Patients","authors":"Kharisma Pratama, Suriadi, Gusti Jhoni Putra, D. Setiawan, A. Djalil, Cau Kim Jiu, Usman, Tisa Gusmiah","doi":"10.2991/ahsr.k.200723.081","DOIUrl":null,"url":null,"abstract":"Diabetic Peripheral Neuropathy (DPN) is one factor which can lead the diabetes mellitus patient to foot ulceration. Early detection is indispensable part to prevent diabetes mellitus patient from foot disorders. vibration perception threshold (VPT) measures can be used to easily and accurately identify presence of DPN. This study was to test the reliability and to evaluate the accuracy of a new vibrometer for detection DPN. A new device (Neovibrometer) was compared with 10g monofilament and tested on a group of DPN and a group of healthy as matched control subjects. Vibration Perception Threshold (VPT) was tested on the plantar surface of the feet. The Neo-vibrometer shows an actual measurement in all test. The Pearson correlation coefficient was 0.94 (P<0.05). The 10g monofilament could also be measured with excellent reliability but only within a limited range of mild to moderate neuropathy, so it appears to be an appropriate screening tool. The measurement-to-measurement intraclass correlation coefficient was 0.93. The new device is accurate and could measure of VPT. It could document loss of sensation in diabetic neuropathy even in the presence of a normal result when it tested by 10g monofilament test. The Neo-vibrometer can be earlier detected of diabetic neuropathy and should be used as the recommended technique in diabetic foot ulcer prevention. Keywords—Nursing Technology, Threshold Testing, Diabetic Peripheral Neuropathy","PeriodicalId":428704,"journal":{"name":"Proceedings of the 1st International Conference on Science, Health, Economics, Education and Technology (ICoSHEET 2019)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1st International Conference on Science, Health, Economics, Education and Technology (ICoSHEET 2019)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2991/ahsr.k.200723.081","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Diabetic Peripheral Neuropathy (DPN) is one factor which can lead the diabetes mellitus patient to foot ulceration. Early detection is indispensable part to prevent diabetes mellitus patient from foot disorders. vibration perception threshold (VPT) measures can be used to easily and accurately identify presence of DPN. This study was to test the reliability and to evaluate the accuracy of a new vibrometer for detection DPN. A new device (Neovibrometer) was compared with 10g monofilament and tested on a group of DPN and a group of healthy as matched control subjects. Vibration Perception Threshold (VPT) was tested on the plantar surface of the feet. The Neo-vibrometer shows an actual measurement in all test. The Pearson correlation coefficient was 0.94 (P<0.05). The 10g monofilament could also be measured with excellent reliability but only within a limited range of mild to moderate neuropathy, so it appears to be an appropriate screening tool. The measurement-to-measurement intraclass correlation coefficient was 0.93. The new device is accurate and could measure of VPT. It could document loss of sensation in diabetic neuropathy even in the presence of a normal result when it tested by 10g monofilament test. The Neo-vibrometer can be earlier detected of diabetic neuropathy and should be used as the recommended technique in diabetic foot ulcer prevention. Keywords—Nursing Technology, Threshold Testing, Diabetic Peripheral Neuropathy
糖尿病周围神经病变患者振动感知阈值测试的护理技术
糖尿病周围神经病变(DPN)是导致糖尿病患者足部溃疡的因素之一。早期发现是预防糖尿病足部疾病不可缺少的环节。振动感知阈值(VPT)可以方便、准确地识别DPN的存在。本研究的目的是检验一种检测DPN的新型测振仪的可靠性和准确性。将一种新装置(Neovibrometer)与10g单丝进行比较,并在一组DPN和一组健康的对照组上进行测试。在足跖表面测试振动感知阈值(VPT)。新测振仪在所有测试中都显示了实际测量值。Pearson相关系数为0.94 (P<0.05)。10g单丝也可以以极好的可靠性测量,但仅在轻度至中度神经病变的有限范围内,因此它似乎是一种合适的筛选工具。测量-测量类内相关系数为0.93。该装置测量精度高,可实现VPT的测量。在10g单丝试验结果正常的情况下,也可记录糖尿病性神经病变的感觉丧失。新测振仪可以早期发现糖尿病神经病变,应作为预防糖尿病足溃疡的推荐技术。关键词:护理技术;阈值检测;糖尿病周围神经病变
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信