{"title":"Corona Discharge Power Losses Measurement Systems in Extra High Voltage Transmissions Lines","authors":"V. Kuchanskyy, I. Zaitsev","doi":"10.1109/ESS50319.2020.9160088","DOIUrl":null,"url":null,"abstract":"In paper present the problem of non-contact measurements of the electric field is very relevant. Such measurements are necessary for remote monitoring of powerful power plants, including power line parameters such as discharge to the corona. In the paper the sequence of calculation power losses of corona discharge is presented. The power losses of corona discharge for extra high voltage transmission lines are calculated. In the work, a system for determining power losses per corona is introduced, the principle of operation of which is based on modern optical means for measuring electric field strength. Shown on the example of really working lines are the values of power losses per corona. To solve the problem of finding the functional dependence of losses on the corona from the voltage and other parameters, it is necessary to create and apply methods and means. After the adopted comments, the work focuses on the urgency of the problem of monitoring the total losses of active power, primarily losses on corona wires. Monitoring the values of power losses per corona by isolating them from the total ones by preliminary measuring the power at the ends of the line is not automated and does not allow real-time use of effective measures and technical means to increase the efficiency of the ultra-high voltage power line. The paper presents the results of calculations through experimental and analytical derived formulas to determine the total, technological and power losses per corona. Based on the results obtained, a comparative analysis of calculations by formulas for subsequent verification was made with the developed system for measuring power losses per corona.","PeriodicalId":169630,"journal":{"name":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS50319.2020.9160088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

In paper present the problem of non-contact measurements of the electric field is very relevant. Such measurements are necessary for remote monitoring of powerful power plants, including power line parameters such as discharge to the corona. In the paper the sequence of calculation power losses of corona discharge is presented. The power losses of corona discharge for extra high voltage transmission lines are calculated. In the work, a system for determining power losses per corona is introduced, the principle of operation of which is based on modern optical means for measuring electric field strength. Shown on the example of really working lines are the values of power losses per corona. To solve the problem of finding the functional dependence of losses on the corona from the voltage and other parameters, it is necessary to create and apply methods and means. After the adopted comments, the work focuses on the urgency of the problem of monitoring the total losses of active power, primarily losses on corona wires. Monitoring the values of power losses per corona by isolating them from the total ones by preliminary measuring the power at the ends of the line is not automated and does not allow real-time use of effective measures and technical means to increase the efficiency of the ultra-high voltage power line. The paper presents the results of calculations through experimental and analytical derived formulas to determine the total, technological and power losses per corona. Based on the results obtained, a comparative analysis of calculations by formulas for subsequent verification was made with the developed system for measuring power losses per corona.
超高压输电线路电晕放电功率损耗测量系统
本文讨论了非接触式电场测量问题。这种测量对于远程监测强大的发电厂是必要的,包括电力线参数,如电晕放电。本文给出了电晕放电功率损耗的计算顺序。计算了超高压输电线路电晕放电的功率损耗。本文介绍了一种基于现代电场强度光学测量方法的电晕功率损耗测定系统。在实际工作线路的示例中显示的是每电晕的功率损耗值。为了解决从电压和其他参数中找到损耗对电晕的函数依赖关系的问题,有必要创建和应用方法和手段。意见通过后,工作重点是监测有功总损耗问题的紧迫性,主要是电晕线的损耗。通过初步测量线路两端的功率,将每电晕的功率损耗与总损耗隔离开来,从而监测电晕的功率损耗值,这不是自动化的,不能实时采用有效的措施和技术手段来提高超高压线路的效率。本文介绍了通过实验和分析推导公式计算的结果,以确定每电晕的总损耗、工艺损耗和功率损耗。根据所得结果,将公式计算结果与所开发的每电晕功率损耗测量系统进行了对比分析,以供后续验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信