Development of a coupling system for medium voltage power line communication in the CENELEC A frequency band

G. Artale, A. Cataliotti, V. Cosentino, S. Guaiana, D. D. Cara, G. Tinè
{"title":"Development of a coupling system for medium voltage power line communication in the CENELEC A frequency band","authors":"G. Artale, A. Cataliotti, V. Cosentino, S. Guaiana, D. D. Cara, G. Tinè","doi":"10.1109/AMPS.2016.7602861","DOIUrl":null,"url":null,"abstract":"In this paper the performances of a new power line communication (PLC) coupling system for medium voltage (MV) smart grids are investigated in the CENELEC A frequency band (i.e. 3-95 kHz). The new coupling solution is based on the use of the capacitive divider of the voltage detecting system (VDS) as PLC coupler to the MV network. According to IEC 61243-5, VDS are worldwide used to reveal the presence of the mains voltage to ensure the safety of the operators. A proper interface circuit has been invented and patented to couple the PLC signal through the VDS. In this way no dedicated MV PLC coupler is required, thus avoiding the related costs of the coupler, of its installation, and those of the associated temporary service interruption. In this paper, a laboratory characterization of the developed coupling solution is presented in the only standardized band, CENELEC A, reserved for the Energy Utilities in Europe.","PeriodicalId":290041,"journal":{"name":"2016 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Workshop on Applied Measurements for Power Systems (AMPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AMPS.2016.7602861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In this paper the performances of a new power line communication (PLC) coupling system for medium voltage (MV) smart grids are investigated in the CENELEC A frequency band (i.e. 3-95 kHz). The new coupling solution is based on the use of the capacitive divider of the voltage detecting system (VDS) as PLC coupler to the MV network. According to IEC 61243-5, VDS are worldwide used to reveal the presence of the mains voltage to ensure the safety of the operators. A proper interface circuit has been invented and patented to couple the PLC signal through the VDS. In this way no dedicated MV PLC coupler is required, thus avoiding the related costs of the coupler, of its installation, and those of the associated temporary service interruption. In this paper, a laboratory characterization of the developed coupling solution is presented in the only standardized band, CENELEC A, reserved for the Energy Utilities in Europe.
CENELEC a频段中压电力线通信耦合系统的研制
本文研究了一种用于中压智能电网的新型电力线通信(PLC)耦合系统在CENELEC a频段(即3-95 kHz)的性能。新的耦合方案是基于使用电压检测系统(VDS)的电容分压器作为中压网络的PLC耦合器。根据IEC 61243-5, VDS在全球范围内用于显示电源电压的存在,以确保操作人员的安全。发明了一种合适的接口电路,通过VDS对PLC信号进行耦合,并申请了专利。这样就不需要专用的中压PLC耦合器,从而避免了耦合器的相关成本、安装成本和相关的临时服务中断成本。在本文中,开发的耦合解决方案的实验室表征是在唯一的标准化波段,CENELEC a,保留在欧洲的能源公用事业。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书