A passive islanding detection approach for distributed generation using rate of change of negative sequence voltage and current

K. M. Kumar, M. Naresh, N. Singh, Ashutosh Kumar Singh
{"title":"A passive islanding detection approach for distributed generation using rate of change of negative sequence voltage and current","authors":"K. M. Kumar, M. Naresh, N. Singh, Ashutosh Kumar Singh","doi":"10.1109/UPCON.2016.7894679","DOIUrl":null,"url":null,"abstract":"In this paper a new passive islanding detection technique is proposed for distributed generation using rate of change of negative sequence voltage and current. The proposed technique is based on the voltage and current measurement at targeted distributed generation (DG). The retrieved voltage and current are converted into symmetrical component through sequence analyzer then rate of change of negative sequence voltage (ROCONSV) and rate of change of negative sequence current (ROCONSC) are calculated for islanding detection. ROCONSV and ROCONSC are tested for different active power mismatching and work effectively even power imbalance is less than 15%. The proposed technique detects islanding very fast less than one cycle. This technique is efficient and free from non detection zone (NDZ).","PeriodicalId":151809,"journal":{"name":"2016 IEEE Uttar Pradesh Section International Conference on Electrical, Computer and Electronics Engineering (UPCON)","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Uttar Pradesh Section International Conference on Electrical, Computer and Electronics Engineering (UPCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPCON.2016.7894679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

In this paper a new passive islanding detection technique is proposed for distributed generation using rate of change of negative sequence voltage and current. The proposed technique is based on the voltage and current measurement at targeted distributed generation (DG). The retrieved voltage and current are converted into symmetrical component through sequence analyzer then rate of change of negative sequence voltage (ROCONSV) and rate of change of negative sequence current (ROCONSC) are calculated for islanding detection. ROCONSV and ROCONSC are tested for different active power mismatching and work effectively even power imbalance is less than 15%. The proposed technique detects islanding very fast less than one cycle. This technique is efficient and free from non detection zone (NDZ).
基于负序电压电流变化率的分布式发电被动孤岛检测方法
本文提出了一种利用负序电压和电流变化率进行分布式发电无源孤岛检测的新方法。该技术是基于目标分布式发电(DG)的电压和电流测量。通过序列分析仪将检索到的电压和电流转换成对称分量,然后计算负序电压变化率(roconv)和负序电流变化率(roconc)进行孤岛检测。对roconv和roconc进行了不同有功失配情况下的测试,在功率不平衡小于15%的情况下均能有效工作。该技术可以在不到一个周期的时间内快速检测孤岛。该技术效率高,无非检测区(NDZ)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信