Distance Relay Tripping Characteristic in Presence of UPFC

S. Jamali, A. Kazemi, H. Shateri
{"title":"Distance Relay Tripping Characteristic in Presence of UPFC","authors":"S. Jamali, A. Kazemi, H. Shateri","doi":"10.1109/PEDES.2006.344327","DOIUrl":null,"url":null,"abstract":"Distance relays are widely used as main and back-up protection for transmission lines. Their operation is based on impedance measurement at the relaying point, which can be affected by several factors, including pre-fault line loading and short circuit levels at the line ends. The problem of growing loads and limited paths for new transmission lines, has been somehow overcome by introduction of flexible AC transmission system (FACTS) devices into the network, which imposes further changes on the measured impedance at the relaying point. This paper presents the effects of unified power flow controller (UPFC), one of FACTS devices, on the measured impedance at the relaying point. In addition to UPFC controlling parameters, its installation point also affects the measured impedance. The variation of the tripping characteristic for different installation points and controlling parameters of UPFC will also be studied.","PeriodicalId":262597,"journal":{"name":"2006 International Conference on Power Electronic, Drives and Energy Systems","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power Electronic, Drives and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDES.2006.344327","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Distance relays are widely used as main and back-up protection for transmission lines. Their operation is based on impedance measurement at the relaying point, which can be affected by several factors, including pre-fault line loading and short circuit levels at the line ends. The problem of growing loads and limited paths for new transmission lines, has been somehow overcome by introduction of flexible AC transmission system (FACTS) devices into the network, which imposes further changes on the measured impedance at the relaying point. This paper presents the effects of unified power flow controller (UPFC), one of FACTS devices, on the measured impedance at the relaying point. In addition to UPFC controlling parameters, its installation point also affects the measured impedance. The variation of the tripping characteristic for different installation points and controlling parameters of UPFC will also be studied.
UPFC存在下距离继电器脱扣特性研究
距离继电器广泛应用于输电线路的主保护和后备保护。它们的运行基于继电点的阻抗测量,这可能受到几个因素的影响,包括故障前线路负载和线路末端的短路水平。通过在网络中引入灵活的交流传输系统(FACTS)设备,已经在某种程度上克服了负载增长和新传输线路径有限的问题,这对继电点的测量阻抗施加了进一步的变化。本文介绍了统一潮流控制器(UPFC)对继电点测量阻抗的影响。除了UPFC控制参数外,其安装位置也会影响被测阻抗。研究了UPFC在不同安装点和控制参数下跳闸特性的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信