A High Dynamic Range ASIC for Time of Flight PET with monolithic crystals

S. G. Fernández, A. Sanmukh, D. Gascón, D. Sánchez, J. Mauricio, R. Graciani, R. Manera, L. Garrido, L. Freixes, J. Marín, O. Vela, José M. Fernández, J. Cela, J. Navarrete, J. Oller, J. Pérez, P. Rato
{"title":"A High Dynamic Range ASIC for Time of Flight PET with monolithic crystals","authors":"S. G. Fernández, A. Sanmukh, D. Gascón, D. Sánchez, J. Mauricio, R. Graciani, R. Manera, L. Garrido, L. Freixes, J. Marín, O. Vela, José M. Fernández, J. Cela, J. Navarrete, J. Oller, J. Pérez, P. Rato","doi":"10.22323/1.343.0085","DOIUrl":null,"url":null,"abstract":"The HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018.","PeriodicalId":400748,"journal":{"name":"Proceedings of Topical Workshop on Electronics for Particle Physics — PoS(TWEPP2018)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Topical Workshop on Electronics for Particle Physics — PoS(TWEPP2018)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.343.0085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The HRFlexToT is a 16-channel ASIC for SiPM anode readout designed for Positron Emission Tomography (PET) applications that features high dynamic range (>8 bits), low input impedance, common cathode connection, high speed and low power (~3.5 mW/ch). The ASIC has been manufactured using XFAB 0.18 mm CMOS technology. The main characteristics of the HRFlexToT, compared to its predecessor, are a new energy measurement readout providing a linear Time Over Threshold (ToT) with an extended dynamic range, lower power consumption and better timing response. Initial measurements show a linearity error below 3%. Single Photon Time Resolution (SPTR) measurements performed using a Hamamatsu MPPC S13360-3050CS (3x3 mm2 pixel, 50 umm cell) shows 30% improvement with respect to the previous version of the ASIC, setting this specification in the order of 141 ps FWHM and reducing 3 times power consumption. It is important to highlight that an SPTR of 141 ps FWHM is, according to the best of our knowledge, the best resolution achieved so far for this sensor. Coincidence Time Resolution (CTR) measurements are expected to be performed during 2018.
一种高动态范围单片晶体飞行时间PET专用集成电路
HRFlexToT是一款用于SiPM阳极读出的16通道ASIC,专为正电子发射断层扫描(PET)应用而设计,具有高动态范围(>8位),低输入阻抗,公共阴极连接,高速和低功耗(~3.5 mW/ch)。ASIC采用XFAB 0.18 mm CMOS技术制造。与前代产品相比,HRFlexToT的主要特点是新的能量测量读数,提供线性阈值时间(ToT),具有扩展的动态范围,更低的功耗和更好的时序响应。初始测量显示线性误差低于3%。使用滨松MPPC S13360-3050CS (3x3 mm2像素,50 umm cell)进行的单光子时间分辨率(SPTR)测量显示,与以前版本的ASIC相比,改进了30%,将此规格设置为141 ps FWHM,降低了3倍的功耗。值得强调的是,据我们所知,目前为止该传感器的最佳分辨率是141 ps FWHM的SPTR。符合时间分辨率(CTR)测量预计在2018年进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信