{"title":"Research on Lactose Concentration Detection Device Based on the Optical Rotation Method","authors":"Zhen Zhou, L. Liang, Kangkang Guo, Zehong Lv","doi":"10.1109/IMCCC.2015.245","DOIUrl":null,"url":null,"abstract":"At present, the process of detecting the sample of the lactose detection method is very complicated due to the strict operation condition, long operation time and expensive equipment. Using the nature of lactose that can rotate the plane of polarization of plane-polarized, a lactose concentration detecting device is designed. The device consists of an experiment platform, a photoelectric receiving and converting module, a data processing module, and a LCD module. Laser, polarizer, detector tube, analyzer and photocell are placed on the experiment platform. The test results show that the performance of the detection device is stable and the error is less than 10% through multiple measure on different solutions at different times. The advantage of the device is mainly manifested in its low cost, compact structure, light weight, small volume, fast response speed, and the convenient operation.","PeriodicalId":438549,"journal":{"name":"2015 Fifth International Conference on Instrumentation and Measurement, Computer, Communication and Control (IMCCC)","volume":"129 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Fifth International Conference on Instrumentation and Measurement, Computer, Communication and Control (IMCCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMCCC.2015.245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

At present, the process of detecting the sample of the lactose detection method is very complicated due to the strict operation condition, long operation time and expensive equipment. Using the nature of lactose that can rotate the plane of polarization of plane-polarized, a lactose concentration detecting device is designed. The device consists of an experiment platform, a photoelectric receiving and converting module, a data processing module, and a LCD module. Laser, polarizer, detector tube, analyzer and photocell are placed on the experiment platform. The test results show that the performance of the detection device is stable and the error is less than 10% through multiple measure on different solutions at different times. The advantage of the device is mainly manifested in its low cost, compact structure, light weight, small volume, fast response speed, and the convenient operation.
基于旋光法的乳糖浓度检测装置研究
目前,乳糖检测法检测样品的过程非常复杂,操作条件严格,操作时间长,设备昂贵。利用乳糖可旋转平面极化平面的特性,设计了一种乳糖浓度检测装置。该装置由实验平台、光电接收转换模块、数据处理模块、LCD模块组成。实验台上放置了激光器、偏光镜、检测管、分析仪和光电管。测试结果表明,通过对不同溶液在不同时间的多次测量,该检测装置性能稳定,误差小于10%。该装置的优点主要表现在成本低、结构紧凑、重量轻、体积小、响应速度快、操作方便。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信