Branched-bus HF power-delay-profile approach of indoor PLC channels

I. C. Papaleonidopoulos, C. Loannou, C. Karagiannopoulos, N. Theodorou
{"title":"Branched-bus HF power-delay-profile approach of indoor PLC channels","authors":"I. C. Papaleonidopoulos, C. Loannou, C. Karagiannopoulos, N. Theodorou","doi":"10.1109/ISPLC.2005.1430485","DOIUrl":null,"url":null,"abstract":"In this paper, the branched-bus topology is evaluated as representative of indoor PLC channels' multipath fading properties. The path amplitude and arrival-time distributions are investigated, as well as ranging of the RMS-delay-spread. Specific analogy between the simplified topology and real indoor power-line network structures is hereupon introduced. The evaluation is performed via comparative simulation between channel routes of a real in-house network and the corresponding branched-bus configurations. A novel computational simulation tool is to this effect employed. Qualitative suitability of the examined topology is indeed verified, and quantitative deductions are extracted as well.","PeriodicalId":153251,"journal":{"name":"International Symposium on Power Line Communications and Its Applications, 2005.","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Power Line Communications and Its Applications, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPLC.2005.1430485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

In this paper, the branched-bus topology is evaluated as representative of indoor PLC channels' multipath fading properties. The path amplitude and arrival-time distributions are investigated, as well as ranging of the RMS-delay-spread. Specific analogy between the simplified topology and real indoor power-line network structures is hereupon introduced. The evaluation is performed via comparative simulation between channel routes of a real in-house network and the corresponding branched-bus configurations. A novel computational simulation tool is to this effect employed. Qualitative suitability of the examined topology is indeed verified, and quantitative deductions are extracted as well.
室内PLC信道的分支总线高频功率延迟分布方法
本文评价了分支总线拓扑结构作为室内PLC信道多径衰落特性的代表。研究了路径幅值和到达时间分布,以及rms -延迟扩展的范围。文中介绍了简化后的拓扑结构与实际室内电力线网络结构的类比。通过对真实内部网络的通道路由和相应的分支总线配置进行比较仿真,进行了评估。为此,采用了一种新颖的计算模拟工具。所检查的拓扑的定性适用性确实得到了验证,并提取了定量推论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信