{"title":"On-line condition monitoring technique for PMSM operated with eccentricity","authors":"J. Rosero, J. Ortega, A. Gacía, L. Romeral","doi":"10.1109/DEMPED.2007.4393077","DOIUrl":null,"url":null,"abstract":"This paper presents a study of the permanent magnet synchronous machine (PMSM) running under eccentricity fault. To carry out the study a two-dimensional (2-D) finite element analysis (FEA) is used. Relationships between stator current induced harmonics and dynamic air-gap eccentricity were investigated. Advanced signal analysis by means of continuous wavelet transforms was performed. Simulation were carried out and compared with experimental results .","PeriodicalId":185737,"journal":{"name":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"172 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2007.4393077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
This paper presents a study of the permanent magnet synchronous machine (PMSM) running under eccentricity fault. To carry out the study a two-dimensional (2-D) finite element analysis (FEA) is used. Relationships between stator current induced harmonics and dynamic air-gap eccentricity were investigated. Advanced signal analysis by means of continuous wavelet transforms was performed. Simulation were carried out and compared with experimental results .