{"title":"A Simple Measurement Method for Frequency-Dependent Impedance and Parasitic Parameters of Common-Mode Chokes","authors":"Peng Hu, Zhongyuan Zhou, Mingjie Sheng, Ya Li, Xiang Zhou, Peng Li, Qi Zhou","doi":"10.1109/ISEMC.2019.8825292","DOIUrl":null,"url":null,"abstract":"One more useful measurement and identification method for common-mode chokes is proposed to analysis frequency-dependent impedance and parasitic parameters information within the balanced frequency range. Equivalent circuit for common-mode chokes is established according to the reciprocal and symmetric physical structure, and S-parameters measured with vector network analyzer have been performed to determine the balanced frequency range. Measurement and identification for frequency-dependent impedance and parasitic parameters has been detailedly discussed, and the corresponding results are obtained through theoretical analysis and calculation. As per the frequency-dependent impedance and parasitic parameters, common-mode and differential-mode signal transmission characteristic within the balanced frequency range can be easlily analyzed, and application performance of common-mode chokes will be improved by optimizing the winding structure or choosing the suitable magnetic material.","PeriodicalId":137753,"journal":{"name":"2019 IEEE International Symposium on Electromagnetic Compatibility, Signal & Power Integrity (EMC+SIPI)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Symposium on Electromagnetic Compatibility, Signal & Power Integrity (EMC+SIPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2019.8825292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
One more useful measurement and identification method for common-mode chokes is proposed to analysis frequency-dependent impedance and parasitic parameters information within the balanced frequency range. Equivalent circuit for common-mode chokes is established according to the reciprocal and symmetric physical structure, and S-parameters measured with vector network analyzer have been performed to determine the balanced frequency range. Measurement and identification for frequency-dependent impedance and parasitic parameters has been detailedly discussed, and the corresponding results are obtained through theoretical analysis and calculation. As per the frequency-dependent impedance and parasitic parameters, common-mode and differential-mode signal transmission characteristic within the balanced frequency range can be easlily analyzed, and application performance of common-mode chokes will be improved by optimizing the winding structure or choosing the suitable magnetic material.