{"title":"Impedance controller and its clinical use of the remote ultrasound diagnostic system","authors":"N. Koizumi, S. Warisawa, H. Hashizume, M. Mitsuishi","doi":"10.1109/ROBOT.2003.1241672","DOIUrl":null,"url":null,"abstract":"A master-slave type remote ultrasound diagnostic system was developed. This paper presents and evaluates its control strategy. There is only one impedance controller that is located in the master site or the slave site or the relay point in the conventional impedance controller. Therefore, the effect of the time lag in transmitting force and position data becomes large in the conventional system. Then we propose an impedance controller to cope with this problem. In the proposed system, the position controller for the slave manipulator is also constructed by means of a velocity-control-based impedance controller. This feature makes it possible to shorten the dead time taken by the slave manipulator to respond for the contact force input. This paper also reports the result of a clinical use of the remote ultrasound diagnostic system. The result of the experiments demonstrates that a medical doctor can diagnose patients as well as the conventional diagnosis.","PeriodicalId":315346,"journal":{"name":"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBOT.2003.1241672","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

A master-slave type remote ultrasound diagnostic system was developed. This paper presents and evaluates its control strategy. There is only one impedance controller that is located in the master site or the slave site or the relay point in the conventional impedance controller. Therefore, the effect of the time lag in transmitting force and position data becomes large in the conventional system. Then we propose an impedance controller to cope with this problem. In the proposed system, the position controller for the slave manipulator is also constructed by means of a velocity-control-based impedance controller. This feature makes it possible to shorten the dead time taken by the slave manipulator to respond for the contact force input. This paper also reports the result of a clinical use of the remote ultrasound diagnostic system. The result of the experiments demonstrates that a medical doctor can diagnose patients as well as the conventional diagnosis.
阻抗控制器及其临床应用的远程超声诊断系统
研制了一种主从式远程超声诊断系统。本文提出并评价了其控制策略。在传统的阻抗控制器中,只有一个位于主站或从站或中继点的阻抗控制器。因此,在传统系统中,时滞对力和位置数据传递的影响很大。然后我们提出了一个阻抗控制器来解决这个问题。在该系统中,采用基于速度控制的阻抗控制器构造了从机械臂的位置控制器。这一特点使得缩短从机械手响应接触力输入的死区时间成为可能。本文还报道了远程超声诊断系统的临床应用结果。实验结果表明,医生不仅可以进行常规诊断,还可以对病人进行诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信