{"title":"Analysis of Intermittent Control for Triple Active Bridge Converter to Suppress Cross-current","authors":"Takanobu Ohno, N. Hoshi","doi":"10.1109/ECCE-Asia49820.2021.9479013","DOIUrl":null,"url":null,"abstract":"Reactive power is transmitted between the power supplies connected with a three-winding transformer of Triple Active Bridge DC/DC converter controlled with conventional phase-shift control. This paper proposes a novel control method based on intermittent control to reduce the cross-current that causes reactive power transmission. In the proposed method, by intermittently turning off all gates of the active bridge connected to the power supply, the remaining two active bridges operate equivalently to Dual Active Bridge DC/DC converter. This method can reduce the reactive power, especially under the conditions where the power distribution of the power supplies is different. Also, this paper describes the experimental results of a 2 kW prototype TAB converter to verify the validity of the proposed method. As a result, it was confirmed that the entire power conversion efficiency was improved by up to 2.5 pt due to suppression of the cross-current.","PeriodicalId":145366,"journal":{"name":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 12th Energy Conversion Congress & Exposition - Asia (ECCE-Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE-Asia49820.2021.9479013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Reactive power is transmitted between the power supplies connected with a three-winding transformer of Triple Active Bridge DC/DC converter controlled with conventional phase-shift control. This paper proposes a novel control method based on intermittent control to reduce the cross-current that causes reactive power transmission. In the proposed method, by intermittently turning off all gates of the active bridge connected to the power supply, the remaining two active bridges operate equivalently to Dual Active Bridge DC/DC converter. This method can reduce the reactive power, especially under the conditions where the power distribution of the power supplies is different. Also, this paper describes the experimental results of a 2 kW prototype TAB converter to verify the validity of the proposed method. As a result, it was confirmed that the entire power conversion efficiency was improved by up to 2.5 pt due to suppression of the cross-current.
三有源桥式变换器抑制交叉电流的间歇控制分析
无功功率在与三有源桥式DC/DC变换器的三绕组变压器连接的电源之间传输,采用传统的移相控制。本文提出了一种基于间歇控制的新型控制方法,以减少引起无功传输的交叉电流。在本文提出的方法中,通过间歇性地关闭连接到电源的有源桥的所有门,其余两个有源桥等效地工作于双有源桥DC/DC变换器。这种方法可以减少无功功率,特别是在电源的功率分布不同的情况下。最后给出了一个2kw的TAB变换器样机的实验结果,验证了所提方法的有效性。结果证实,由于抑制了交叉电流,整个功率转换效率提高了2.5 pt。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信