S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Pătru, R. Dinu
{"title":"Considerations on Electromagnetic Disturbances Produced by LEDs Light Sources","authors":"S. Digă, Nicolae Digă, P. Mircea, M. Nicolae, I. Pătru, R. Dinu","doi":"10.1109/PQEMC-LF58184.2023.10211262","DOIUrl":null,"url":null,"abstract":"In this paper, a series of theoretical and practical aspects are presented in the first instance that refer to the performances of a semi-anechoic chamber that exists within the profile laboratory at the National Institute for Research, Development and Testing in Electrical Engineering – ICMET Craiova. Measurements of electromagnetic disturbances were carried out at this location, which two LED lighting devices, namely a Flexi LED & Flash light tube and a LED projector, transmitted into the power supply network. Then the authors made a comparative analysis of the practical results obtained from these measurements of electromagnetic disturbances transmitted by conduction in one of the frequency domains (from 9 kHz to 30 MHz) provided by the reference standards.","PeriodicalId":341783,"journal":{"name":"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)","volume":"22 39","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 Power Quality and Electromagnetic Compatibility at Low Frequency (PQEMC-LF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQEMC-LF58184.2023.10211262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, a series of theoretical and practical aspects are presented in the first instance that refer to the performances of a semi-anechoic chamber that exists within the profile laboratory at the National Institute for Research, Development and Testing in Electrical Engineering – ICMET Craiova. Measurements of electromagnetic disturbances were carried out at this location, which two LED lighting devices, namely a Flexi LED & Flash light tube and a LED projector, transmitted into the power supply network. Then the authors made a comparative analysis of the practical results obtained from these measurements of electromagnetic disturbances transmitted by conduction in one of the frequency domains (from 9 kHz to 30 MHz) provided by the reference standards.