The impact of an additional implant under the saddle of removable partial dentures in Kennedy Class II edentulism on oral health-related quality of life and oral function: a case series report.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Toshifumi Nogawa, Yoshiyuki Takayama, Makoto Ishikawa, Atsuro Yokoyama
{"title":"The impact of an additional implant under the saddle of removable partial dentures in Kennedy Class II edentulism on oral health-related quality of life and oral function: a case series report.","authors":"Toshifumi Nogawa,&nbsp;Yoshiyuki Takayama,&nbsp;Makoto Ishikawa,&nbsp;Atsuro Yokoyama","doi":"10.1186/s40729-022-00463-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Implant-supported removable partial dentures (ISRPDs) provide effective prosthodontic treatment for partially edentulous patients. ISRPDs offer greater patient satisfaction and better oral function compared with removable partial dentures (RPDs) by enhancing denture stability and support. However, few clinical studies have focused on RPD design in patients with mandibular Kennedy Class II edentulism. The aim of this case reports was to investigate the oral function, oral health-related quality of life, and satisfaction of four patients with unilateral distal-extension mandibular RPDs with the same design which were replaced with ISRPDs. In addition, we investigated how each patient's evaluation varied with the change from RPD to ISRPD.</p><p><strong>Case presentation: </strong>Four patients had unilateral distal-extension mandibular edentulism and were missing the first and second molars and the first and second premolars. They received one implant (4.0 mm in diameter, 8.0 mm in length; IAT EXA PLUS Bone level; Nippon Piston Ring Co. Ltd, Saitama, Japan) at the position equivalent to the first molar in the edentulous residual ridge perpendicular to the occlusal plane. Implant position was determined by surgical guide plate. RPDs were fabricated after the residual mucosal membrane had healed. The basic design of the RPD was as follows: a cobalt-chromium alloy cast metal framework denture with a lingual bar as the major connector, a double Akers clasp on the molars and an auxiliary retainer on the premolar as indirect retainers, and a wrought wire clasp and a cast cingulum rest (combination clasp) as direct retainers. Masticatory performance, occlusal force, oral health-related quality of life, and satisfaction were estimated at baseline, and at time points after insertion of the RPD and after insertion of the adapted ISRPD. Each evaluation item showed a tendency for improvement on insertion of the new RPD. Masticatory performance and satisfaction tended to be better after insertion of the ISRPD than after insertion of the RPD.</p><p><strong>Conclusion: </strong>Our findings suggest that ISRPDs provided better patient satisfaction and masticatory performance than RPDs in patients with mandibular Kennedy Class II edentulism. Trial registration UMIN Clinical Trials Registry and Japan Registry of Clinical Trials, UMIN000025283 and jRCTs012180003. Registered 19 February 2016 and 17 December 2018, https://www.umin.ac.jp/ and https://jrct.niph.go.jp/.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9715894/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-022-00463-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Implant-supported removable partial dentures (ISRPDs) provide effective prosthodontic treatment for partially edentulous patients. ISRPDs offer greater patient satisfaction and better oral function compared with removable partial dentures (RPDs) by enhancing denture stability and support. However, few clinical studies have focused on RPD design in patients with mandibular Kennedy Class II edentulism. The aim of this case reports was to investigate the oral function, oral health-related quality of life, and satisfaction of four patients with unilateral distal-extension mandibular RPDs with the same design which were replaced with ISRPDs. In addition, we investigated how each patient's evaluation varied with the change from RPD to ISRPD.

Case presentation: Four patients had unilateral distal-extension mandibular edentulism and were missing the first and second molars and the first and second premolars. They received one implant (4.0 mm in diameter, 8.0 mm in length; IAT EXA PLUS Bone level; Nippon Piston Ring Co. Ltd, Saitama, Japan) at the position equivalent to the first molar in the edentulous residual ridge perpendicular to the occlusal plane. Implant position was determined by surgical guide plate. RPDs were fabricated after the residual mucosal membrane had healed. The basic design of the RPD was as follows: a cobalt-chromium alloy cast metal framework denture with a lingual bar as the major connector, a double Akers clasp on the molars and an auxiliary retainer on the premolar as indirect retainers, and a wrought wire clasp and a cast cingulum rest (combination clasp) as direct retainers. Masticatory performance, occlusal force, oral health-related quality of life, and satisfaction were estimated at baseline, and at time points after insertion of the RPD and after insertion of the adapted ISRPD. Each evaluation item showed a tendency for improvement on insertion of the new RPD. Masticatory performance and satisfaction tended to be better after insertion of the ISRPD than after insertion of the RPD.

Conclusion: Our findings suggest that ISRPDs provided better patient satisfaction and masticatory performance than RPDs in patients with mandibular Kennedy Class II edentulism. Trial registration UMIN Clinical Trials Registry and Japan Registry of Clinical Trials, UMIN000025283 and jRCTs012180003. Registered 19 February 2016 and 17 December 2018, https://www.umin.ac.jp/ and https://jrct.niph.go.jp/.

Abstract Image

Abstract Image

Kennedy II类义齿患者可摘局部义齿鞍下附加种植体对口腔健康相关生活质量和口腔功能的影响:一个病例系列报告
背景:种植支撑可摘局部义齿为部分无牙患者提供了一种有效的修复方法。与可摘局部义齿相比,可摘局部义齿通过增强义齿的稳定性和支撑力,提高了患者的满意度和口腔功能。然而,很少有临床研究关注下颌骨Kennedy II类全牙症患者的RPD设计。本病例报告的目的是调查4例设计相同的单侧远伸下颌骨rpd患者的口腔功能、口腔健康相关生活质量和满意度。此外,我们调查了每位患者的评估如何随着从RPD到ISRPD的变化而变化。病例介绍:4例单侧下颌远伸全牙症患者缺失第一、第二磨牙和第一、第二前磨牙。他们接受一个种植体(直径4.0 mm,长度8.0 mm;IAT EXA +骨水平;Nippon活塞环株式会社,埼玉,日本)的位置相当于第一磨牙在无牙残牙脊垂直于咬合面。种植体位置由手术引导板确定。待残余粘膜愈合后制作rpd。RPD的基本设计如下:钴铬合金铸造金属框架义齿,以舌杆为主要连接器,臼齿上的双埃克斯卡环和前磨牙上的辅助固位器作为间接固位器,锻造金属卡环和铸造带托(组合卡环)作为直接固位器。在基线、置入RPD后和置入适配的ISRPD后的时间点评估咀嚼性能、咬合力、口腔健康相关生活质量和满意度。各评价项目在新RPD插入后均有改善的趋势。置入ISRPD后,咀嚼功能和满意度优于置入RPD后。结论:我们的研究结果表明,ISRPDs比rpd提供了更好的患者满意度和咀嚼性能。试验注册UMIN临床试验注册中心和日本临床试验注册中心,UMIN000025283和jRCTs012180003。2016年2月19日和2018年12月17日注册,https://www.umin.ac.jp/和https://jrct.niph.go.jp/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信