Quantification of Lung Tumor Motion and Optimization of Treatment.

Q3 Medicine
Milovan Savanović, Bojan Štrbac, Dražan Jaroš, Mauro Loi, Florence Huguet, Jean-Noël Foulquier
{"title":"Quantification of Lung Tumor Motion and Optimization of Treatment.","authors":"Milovan Savanović,&nbsp;Bojan Štrbac,&nbsp;Dražan Jaroš,&nbsp;Mauro Loi,&nbsp;Florence Huguet,&nbsp;Jean-Noël Foulquier","doi":"10.31661/jbpe.v0i0.2102-1278","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Mobility of lung tumors is induced by respiration and causes inadequate dose coverage.</p><p><strong>Objective: </strong>This study quantified lung tumor motion, velocity, and stability for small (≤5 cm) and large (>5 cm) tumors to adapt radiation therapy techniques for lung cancer patients.</p><p><strong>Material and methods: </strong>In this retrospective study, 70 patients with lung cancer were included that 50 and 20 patients had a small and large gross tumor volume (GTV). To quantify the tumor motion and velocity in the upper lobe (UL) and lower lobe (LL) for the central region (CR) and a peripheral region (PR), the GTV was contoured in all ten respiratory phases, using 4D-CT.</p><p><strong>Results: </strong>The amplitude of tumor motion was greater in the LL, with motion in the superior-inferior (SI) direction compared to the UL, with an elliptical motion for small and large tumors. Tumor motion was greater in the CR, rather than in the PR, by 63% and 49% in the UL compared to 50% and 38% in the LL, for the left and right lung. The maximum tumor velocity for a small GTV was 44.1 mm/s in the LL (CR), decreased to 4 mm/s for both ULs (PR), and a large GTV ranged from 0.4 to 9.4 mm/s.</p><p><strong>Conclusion: </strong>The tumor motion and velocity depend on the tumor localization and the greater motion was in the CR for both lobes due to heart contribution. The tumor velocity and stability can help select the best technique for motion management during radiation therapy.</p>","PeriodicalId":38035,"journal":{"name":"Journal of Biomedical Physics and Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/aa/f9/JBPE-13-65.PMC9923245.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31661/jbpe.v0i0.2102-1278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Mobility of lung tumors is induced by respiration and causes inadequate dose coverage.

Objective: This study quantified lung tumor motion, velocity, and stability for small (≤5 cm) and large (>5 cm) tumors to adapt radiation therapy techniques for lung cancer patients.

Material and methods: In this retrospective study, 70 patients with lung cancer were included that 50 and 20 patients had a small and large gross tumor volume (GTV). To quantify the tumor motion and velocity in the upper lobe (UL) and lower lobe (LL) for the central region (CR) and a peripheral region (PR), the GTV was contoured in all ten respiratory phases, using 4D-CT.

Results: The amplitude of tumor motion was greater in the LL, with motion in the superior-inferior (SI) direction compared to the UL, with an elliptical motion for small and large tumors. Tumor motion was greater in the CR, rather than in the PR, by 63% and 49% in the UL compared to 50% and 38% in the LL, for the left and right lung. The maximum tumor velocity for a small GTV was 44.1 mm/s in the LL (CR), decreased to 4 mm/s for both ULs (PR), and a large GTV ranged from 0.4 to 9.4 mm/s.

Conclusion: The tumor motion and velocity depend on the tumor localization and the greater motion was in the CR for both lobes due to heart contribution. The tumor velocity and stability can help select the best technique for motion management during radiation therapy.

肺肿瘤运动的量化与治疗的优化。
背景:肺肿瘤的移动性是由呼吸引起的,导致剂量覆盖不足。目的:本研究量化小(≤5cm)和大(> 5cm)肿瘤的运动、速度和稳定性,以适应肺癌患者的放射治疗技术。材料与方法:本研究纳入70例肺癌患者,其中GTV (gross tumor volume,总肿瘤体积)大小各50例和20例。为了量化肿瘤在中央区(CR)和外周区(PR)的上肺叶(UL)和下肺叶(LL)的运动和速度,使用4D-CT绘制了所有十个呼吸期的GTV轮廓。结果:左左肿瘤运动幅度大于左左,呈上下(SI)方向运动,大小肿瘤呈椭圆形运动。左、右肺的肿瘤运动在CR大于PR,左、右肺分别比左、右肺大63%和49%,而左、右肺分别为50%和38%。小GTV的最大肿瘤速度在LL (CR)为44.1 mm/s,在ULs (PR)为4 mm/s,而大GTV的范围为0.4 ~ 9.4 mm/s。结论:肿瘤的运动和速度取决于肿瘤的定位,由于心脏的贡献,两叶CR的运动更大。肿瘤的速度和稳定性可以帮助选择放射治疗期间运动管理的最佳技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Biomedical Physics and Engineering
Journal of Biomedical Physics and Engineering Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.90
自引率
0.00%
发文量
64
审稿时长
10 weeks
期刊介绍: The Journal of Biomedical Physics and Engineering (JBPE) is a bimonthly peer-reviewed English-language journal that publishes high-quality basic sciences and clinical research (experimental or theoretical) broadly concerned with the relationship of physics to medicine and engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信