Retrospective comparison of the effects of laryngeal mask and endotracheal tube on some cardio-respiratory variables in pet rabbits undergoing anaesthesia for elective gonadectomy.

IF 1.9 2区 农林科学 Q2 VETERINARY SCIENCES
Luca Bellini, Magdalena Schrank, Irene Alessandra Veladiano, Barbara Contiero, Antonio Mollo
{"title":"Retrospective comparison of the effects of laryngeal mask and endotracheal tube on some cardio-respiratory variables in pet rabbits undergoing anaesthesia for elective gonadectomy.","authors":"Luca Bellini,&nbsp;Magdalena Schrank,&nbsp;Irene Alessandra Veladiano,&nbsp;Barbara Contiero,&nbsp;Antonio Mollo","doi":"10.1186/s13028-023-00673-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endotracheal intubation in rabbits is challenging and supraglottic airway devices, such as laryngeal masks (LMA), represent an alternative as they are easy to insert, and do not stimulate the larynx requiring therefore a lighter plane of anaesthesia for their insertion and positioning than the endotracheal tubes. We investigated whether, compared to an endotracheal tube, the LMA can reduce the negative effects of general anaesthetics on some cardiovascular and respiratory parameters routinely monitored in rabbits anaesthetized for elective gonadectomy. The records of 21 adult mixed breed pet rabbits were collected retrospectively. Rabbits were divided in two groups based on the type of airway device used. A laryngeal mask secured the airway in group LMA (n = 11), and in group ETT (n = 10) an endotracheal tube was used. The amount of propofol used before successful insertion of the airway device was recorded. A pitot-based spirometer was connected and ventilatory variables were measured immediately after insertion. Pulse rate, non-invasive arterial blood pressure, haemoglobin oxygen saturation, respiratory rate, end-tidal carbon dioxide and volatile anaesthetic consumption were also monitored during the surgical procedure; extubation time was noted as well.</p><p><strong>Results: </strong>The use of LMA required significantly less propofol (0.8 to 4 mg/kg) for insertion than the ETT (1.2 to 5.6 mg/kg), and the difference was statistically significant (P < 0.01). No differences were observed in ventilatory variables measured immediately after airway positioning. Intraoperatively, there were no differences between groups for respiratory and cardiovascular variables, and amount of isoflurane administered. In all rabbits mean and diastolic blood pressure progressively decreased during surgery. Mean extubation time was shorter in group LMA (6 ± 2 min) than group ETT (8 ± 3 min, P < 0.01).</p><p><strong>Conclusion: </strong>The airway device did not clinically affect the cardiovascular and respiratory variables during anaesthesia. Intraoperative hypoventilation was observed in most rabbits regardless of the device being used; therefore ventilatory support may be required. Rabbits with the laryngeal masks were extubated earlier.</p>","PeriodicalId":7181,"journal":{"name":"Acta Veterinaria Scandinavica","volume":"65 1","pages":"10"},"PeriodicalIF":1.9000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9976375/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Veterinaria Scandinavica","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1186/s13028-023-00673-2","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Endotracheal intubation in rabbits is challenging and supraglottic airway devices, such as laryngeal masks (LMA), represent an alternative as they are easy to insert, and do not stimulate the larynx requiring therefore a lighter plane of anaesthesia for their insertion and positioning than the endotracheal tubes. We investigated whether, compared to an endotracheal tube, the LMA can reduce the negative effects of general anaesthetics on some cardiovascular and respiratory parameters routinely monitored in rabbits anaesthetized for elective gonadectomy. The records of 21 adult mixed breed pet rabbits were collected retrospectively. Rabbits were divided in two groups based on the type of airway device used. A laryngeal mask secured the airway in group LMA (n = 11), and in group ETT (n = 10) an endotracheal tube was used. The amount of propofol used before successful insertion of the airway device was recorded. A pitot-based spirometer was connected and ventilatory variables were measured immediately after insertion. Pulse rate, non-invasive arterial blood pressure, haemoglobin oxygen saturation, respiratory rate, end-tidal carbon dioxide and volatile anaesthetic consumption were also monitored during the surgical procedure; extubation time was noted as well.

Results: The use of LMA required significantly less propofol (0.8 to 4 mg/kg) for insertion than the ETT (1.2 to 5.6 mg/kg), and the difference was statistically significant (P < 0.01). No differences were observed in ventilatory variables measured immediately after airway positioning. Intraoperatively, there were no differences between groups for respiratory and cardiovascular variables, and amount of isoflurane administered. In all rabbits mean and diastolic blood pressure progressively decreased during surgery. Mean extubation time was shorter in group LMA (6 ± 2 min) than group ETT (8 ± 3 min, P < 0.01).

Conclusion: The airway device did not clinically affect the cardiovascular and respiratory variables during anaesthesia. Intraoperative hypoventilation was observed in most rabbits regardless of the device being used; therefore ventilatory support may be required. Rabbits with the laryngeal masks were extubated earlier.

喉罩与气管插管对家兔择期性腺切除术麻醉后心肺指标影响的回顾性比较。
背景:兔的气管插管具有挑战性,声门上气道装置,如喉罩(LMA),是一种替代方法,因为它们易于插入,并且不刺激喉部,因此需要比气管插管更轻的麻醉平面来插入和定位。我们研究了与气管插管相比,LMA是否可以减少全麻对兔择期性腺切除术麻醉后常规监测的一些心血管和呼吸参数的负面影响。对21只成年杂交家兔进行了回顾性调查。根据使用的气道设备类型将家兔分为两组。LMA组(n = 11)使用喉罩固定气道,ETT组(n = 10)使用气管内插管。记录成功插入气道装置前异丙酚的用量。连接以皮托为基础的肺活量计,并在插入后立即测量通气变量。在手术过程中还监测脉搏率、无创动脉血压、血红蛋白氧饱和度、呼吸率、潮末二氧化碳和挥发性麻醉剂消耗;拔管时间也被记录。结果:使用LMA时使用的异丙酚(0.8 ~ 4 mg/kg)明显少于使用ETT时使用的异丙酚(1.2 ~ 5.6 mg/kg),差异有统计学意义(P)结论:该气道装置在临床上对麻醉期间的心血管和呼吸变量没有影响。无论使用何种器械,大多数家兔术中通气不足;因此,可能需要通气支持。戴喉罩的兔较早拔管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Veterinaria Scandinavica
Acta Veterinaria Scandinavica 农林科学-兽医学
CiteScore
3.60
自引率
0.00%
发文量
28
审稿时长
18-36 weeks
期刊介绍: Acta Veterinaria Scandinavica is an open access journal encompassing all aspects of veterinary research and medicine of domestic and wild animals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信