Lucy Bai, Ola Lundström, Hemming Johansson, Farid Meybodi, Brita Arver, Kerstin Sandelin, Marie Wickman, Yvonne Brandberg
{"title":"Clinical assessment of breast symmetry and aesthetic outcome: can 3D imaging be the gold standard?","authors":"Lucy Bai, Ola Lundström, Hemming Johansson, Farid Meybodi, Brita Arver, Kerstin Sandelin, Marie Wickman, Yvonne Brandberg","doi":"10.1080/2000656X.2021.2024553","DOIUrl":null,"url":null,"abstract":"<p><p>There is a lack of an accurate standardised objective method to assess aesthetic outcome after breast surgery. In this methodological study, we investigated the intra- and inter-observer reproducibility of breast symmetry and volume assessed using three-dimensional surface imaging (3D-SI), evaluated the reproducibility depending on imaging posture, and proposed a new combined volume-shape-symmetry (<math><mi>VSS</mi></math>) parameter. Images were acquired using the VECTRA XT 3D imaging system, and analysed by two observers using VECTRA Analysis Module. Breast symmetry was measured through the root mean square distance. All women had undergone bilateral risk-reducing mastectomy and immediate breast reconstruction. The reproducibility and correlations of breast symmetry and volume measurements were compared using Bland-Altman's plots and tested with Spearman's rank correlation coefficient. 3D surface images of 58 women were analysed (348 symmetry measurements, 696 volume measurements). The intra-observer reproducibility of breast symmetry measurements was substantial-excellent, the inter-observer reproducibility was substantial, and the inter-posture reproducibility was substantial. For measurements of breast volumes, the intra-observer reproducibility was excellent, the inter-observer reproducibility was moderate-substantial, and the inter-posture reproducibility was substantial-excellent. The intra-observer reproducibility of <math><mi>VSS</mi></math> was excellent while the inter-observer reproducibility was substantial for both observers, independent of posture. There were no statistically strong correlations between breast symmetry and volume differences. The intra-observer reproducibility was found to be substantial-excellent for several 3D-SI measurements independent of imaging posture. However, the inter-observer reproducibility was lower than the intra-observer reproducibility, indicating that 3D-SI in its present form is not a great assessment for symmetry.</p>","PeriodicalId":16847,"journal":{"name":"Journal of Plastic Surgery and Hand Surgery","volume":"57 1-6","pages":"145-152"},"PeriodicalIF":1.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Plastic Surgery and Hand Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/2000656X.2021.2024553","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 5
Abstract
There is a lack of an accurate standardised objective method to assess aesthetic outcome after breast surgery. In this methodological study, we investigated the intra- and inter-observer reproducibility of breast symmetry and volume assessed using three-dimensional surface imaging (3D-SI), evaluated the reproducibility depending on imaging posture, and proposed a new combined volume-shape-symmetry () parameter. Images were acquired using the VECTRA XT 3D imaging system, and analysed by two observers using VECTRA Analysis Module. Breast symmetry was measured through the root mean square distance. All women had undergone bilateral risk-reducing mastectomy and immediate breast reconstruction. The reproducibility and correlations of breast symmetry and volume measurements were compared using Bland-Altman's plots and tested with Spearman's rank correlation coefficient. 3D surface images of 58 women were analysed (348 symmetry measurements, 696 volume measurements). The intra-observer reproducibility of breast symmetry measurements was substantial-excellent, the inter-observer reproducibility was substantial, and the inter-posture reproducibility was substantial. For measurements of breast volumes, the intra-observer reproducibility was excellent, the inter-observer reproducibility was moderate-substantial, and the inter-posture reproducibility was substantial-excellent. The intra-observer reproducibility of was excellent while the inter-observer reproducibility was substantial for both observers, independent of posture. There were no statistically strong correlations between breast symmetry and volume differences. The intra-observer reproducibility was found to be substantial-excellent for several 3D-SI measurements independent of imaging posture. However, the inter-observer reproducibility was lower than the intra-observer reproducibility, indicating that 3D-SI in its present form is not a great assessment for symmetry.
期刊介绍:
The purpose of the Journal of Plastic Surgery and Hand Surgery is to serve as an international forum for plastic surgery, hand surgery and related research. Interest is focused on original articles on basic research and clinical evaluation.
The scope of the journal comprises:
• Articles concerning operative methods and follow-up studies
• Research articles on subjects related to plastic and hand surgery
• Articles on cranio-maxillofacial surgery, including cleft lip and palate surgery.
Extended issues are published occasionally, dealing with special topics such as microvascular surgery, craniofacial surgery, or burns. Supplements, usually doctoral theses, may also be published.
The journal is published for the Acta Chirurgica Scandinavica society and sponsored by the Key Foundation, Sweden.
The journal was previously published as Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery.