Development of computational models for microtesla-level magnetic brain scanning: a novel avenue for device development.

Shane Shahrestani, Gabriel Zada, Yu-Chong Tai
{"title":"Development of computational models for microtesla-level magnetic brain scanning: a novel avenue for device development.","authors":"Shane Shahrestani,&nbsp;Gabriel Zada,&nbsp;Yu-Chong Tai","doi":"10.1186/s42490-022-00058-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Detection of locally increased blood concentration and perfusion is critical for assessment of functional cortical activity as well as diagnosis of conditions such as intracerebral hemorrhage (ICH). Current paradigms for assessment of regional blood concentration in the brain rely on computed tomography (CT), magnetic resonance imaging (MRI), and perfusion blood oxygen level dependent functional magnetic resonance imaging (BOLD-fMRI).</p><p><strong>Results: </strong>In this study, we developed computational models to test the feasibility of novel magnetic sensors capable of detecting hemodynamic changes within the brain on a microtesla-level. We show that low-field magnetic sensors can accurately detect changes in magnetic flux density and eddy current damping signals resulting from increases in local blood concentration. These models predicted that blood volume changes as small as 1.26 mL may be resolved by the sensors, implying potential use for diagnosis of ICH and assessment of regional blood flow as a proxy for cerebral metabolism and neuronal activity. We then translated findings from our computational model to demonstrate feasibility of accurate detection of modeled ICH in a simulated human cadaver setting.</p><p><strong>Conclusions: </strong>Overall, microtesla-level magnetic scanning is feasible, safe, and has distinct advantages compared to current standards of care. Computational modeling may facilitate rapid prototype development and testing of novel medical devices with minimal risk to human participants prior to device construction and clinical trials.</p>","PeriodicalId":72425,"journal":{"name":"BMC biomedical engineering","volume":"4 1","pages":"1"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8785482/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42490-022-00058-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Detection of locally increased blood concentration and perfusion is critical for assessment of functional cortical activity as well as diagnosis of conditions such as intracerebral hemorrhage (ICH). Current paradigms for assessment of regional blood concentration in the brain rely on computed tomography (CT), magnetic resonance imaging (MRI), and perfusion blood oxygen level dependent functional magnetic resonance imaging (BOLD-fMRI).

Results: In this study, we developed computational models to test the feasibility of novel magnetic sensors capable of detecting hemodynamic changes within the brain on a microtesla-level. We show that low-field magnetic sensors can accurately detect changes in magnetic flux density and eddy current damping signals resulting from increases in local blood concentration. These models predicted that blood volume changes as small as 1.26 mL may be resolved by the sensors, implying potential use for diagnosis of ICH and assessment of regional blood flow as a proxy for cerebral metabolism and neuronal activity. We then translated findings from our computational model to demonstrate feasibility of accurate detection of modeled ICH in a simulated human cadaver setting.

Conclusions: Overall, microtesla-level magnetic scanning is feasible, safe, and has distinct advantages compared to current standards of care. Computational modeling may facilitate rapid prototype development and testing of novel medical devices with minimal risk to human participants prior to device construction and clinical trials.

Abstract Image

Abstract Image

Abstract Image

微特斯拉级脑磁扫描计算模型的发展:设备开发的新途径。
背景:局部血药浓度和血流灌注增加的检测对于评估皮质功能活动以及诊断脑出血(ICH)等疾病至关重要。目前评估脑区域血药浓度的方法主要依赖于计算机断层扫描(CT)、磁共振成像(MRI)和灌注血氧水平依赖的功能磁共振成像(BOLD-fMRI)。结果:在这项研究中,我们开发了计算模型来测试能够在微特斯拉水平上检测大脑内血流动力学变化的新型磁传感器的可行性。我们表明,低场磁传感器可以准确地检测到由局部血浓度增加引起的磁通密度和涡流阻尼信号的变化。这些模型预测,小至1.26 mL的血容量变化可能被传感器分辨出来,这意味着可能用于诊断脑出血和评估区域血流量,作为脑代谢和神经元活动的代理。然后,我们将计算模型的结果转化为在模拟人类尸体环境中准确检测模拟ICH的可行性。结论:总的来说,微特斯拉水平的磁扫描是可行的,安全的,与目前的护理标准相比具有明显的优势。计算建模可以促进新型医疗设备的快速原型开发和测试,在设备构建和临床试验之前对人类参与者的风险最小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
19 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信