{"title":"Worth the Wait? Time Course of Supine Shifts in Body Water Compartments on Variables of Bioelectrical Impedance Analysis.","authors":"Jeremy B Ducharme, Holly Hall, Zachary J Fennel, Avadney Gerard-Osbourne, Jonathan M Houck, Chloe Clark, Ann L Gibson","doi":"10.2478/joeb-2022-0014","DOIUrl":null,"url":null,"abstract":"<p><p>Bioelectrical impedance analysis (BIA) reference values are based on supine assessments. Little is known regarding the effects of time course shifts in body water compartments after assuming a supine position. The aim of this study was to characterize these effects and provide recommendations regarding the optimal waiting time to perform BIA. Thirty-eight healthy adults underwent BIA via the RJL Quantum Legacy analyzer immediately upon lying down and every 5 minutes for 15 minutes. Differences in resistance (R), reactance (Xc), intracellular (ICW), extracellular (ECW), total body water (TBW), body fat percentage (%BF), and phase angle (PhA) were assessed. There were small but significant increases in R, Xc, and %BF (all p<0.001), as well as small but significant decreases in ICW, ECW, and TBW (all p<0.001) over 15 minutes. No difference was observed for PhA (p=0.065). Average values changed over 15 minutes by +7.14Ω, +1.36Ω, -0.2L, -0.2L, -0.4L, +0.05° and +0.1% for R, Xc, ICW, ECW, TBW, PhA and %BF, respectively. BIA measurements are affected by shifts in body water compartments after assuming a supine position, but these differences lack clinical significance in healthy adults. Technicians working with healthy adults can perform BIA within 15 minutes after participants assume a supine position.</p>","PeriodicalId":38125,"journal":{"name":"Journal of Electrical Bioimpedance","volume":"13 1","pages":"96-105"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837868/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Bioimpedance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/joeb-2022-0014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
Abstract
Bioelectrical impedance analysis (BIA) reference values are based on supine assessments. Little is known regarding the effects of time course shifts in body water compartments after assuming a supine position. The aim of this study was to characterize these effects and provide recommendations regarding the optimal waiting time to perform BIA. Thirty-eight healthy adults underwent BIA via the RJL Quantum Legacy analyzer immediately upon lying down and every 5 minutes for 15 minutes. Differences in resistance (R), reactance (Xc), intracellular (ICW), extracellular (ECW), total body water (TBW), body fat percentage (%BF), and phase angle (PhA) were assessed. There were small but significant increases in R, Xc, and %BF (all p<0.001), as well as small but significant decreases in ICW, ECW, and TBW (all p<0.001) over 15 minutes. No difference was observed for PhA (p=0.065). Average values changed over 15 minutes by +7.14Ω, +1.36Ω, -0.2L, -0.2L, -0.4L, +0.05° and +0.1% for R, Xc, ICW, ECW, TBW, PhA and %BF, respectively. BIA measurements are affected by shifts in body water compartments after assuming a supine position, but these differences lack clinical significance in healthy adults. Technicians working with healthy adults can perform BIA within 15 minutes after participants assume a supine position.