Florian Rathe, Rüdiger Junker, Christian Heumann, Julia Blumenröhr, Thorsten Auschill, Nicole Arweiler, Markus Schlee
{"title":"Long-term effects of titanium-base abutments on peri-implant health: A 5-year randomised controlled trial.","authors":"Florian Rathe, Rüdiger Junker, Christian Heumann, Julia Blumenröhr, Thorsten Auschill, Nicole Arweiler, Markus Schlee","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Titanium bases are used frequently in daily practice for bonding to CAD/CAM abutments or crowns. Due to intimate contact between the adhesive gap of the titanium-base abutment and the peri-implant bone, the physical and chemical characteristics of the bonding material, or the gap itself, may affect peri-implant inflammatory reactions. The present study therefore aimed to examine the long-term effects of individualised abutments bonded to titanium bases on peri-implant health.</p><p><strong>Materials and methods: </strong>A total of 24 patients, each with one test and one control abutment, participated in the present prospective, single-blind, randomised controlled clinical trial. The test abutments were CAD/CAM titanium abutments bonded to titanium bases. As the control abutments were individualised, one-piece CAD/CAM titanium abutments were used. Clinical and radiographic parameters were assessed at abutment insertion and then on a yearly basis over the following 5 years.</p><p><strong>Results: </strong>No significant differences in marginal bone level were observed between the titanium-base and one-piece abutments at any of the follow-up time points; however, when intragroup marginal bone levels were compared to the baseline values, significant differences were found at several follow-up time points. Intergroup differences were only found to be significant for pocket depth at the 4- (P = 0.006) and 5-year follow-ups (P = 0.024), favouring titanium-base abutments.</p><p><strong>Conclusions: </strong>Within the limitations of the present study, it appears that the peri-implant tissues of this specific patient cohort responded to titanium-base abutments in a rather similar manner to one-piece abutments over a 5-year period; however, no definitive conclusions can be drawn due to the low power of the present study.</p>","PeriodicalId":73463,"journal":{"name":"International journal of oral implantology (Berlin, Germany)","volume":"15 2","pages":"167-179"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral implantology (Berlin, Germany)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Titanium bases are used frequently in daily practice for bonding to CAD/CAM abutments or crowns. Due to intimate contact between the adhesive gap of the titanium-base abutment and the peri-implant bone, the physical and chemical characteristics of the bonding material, or the gap itself, may affect peri-implant inflammatory reactions. The present study therefore aimed to examine the long-term effects of individualised abutments bonded to titanium bases on peri-implant health.
Materials and methods: A total of 24 patients, each with one test and one control abutment, participated in the present prospective, single-blind, randomised controlled clinical trial. The test abutments were CAD/CAM titanium abutments bonded to titanium bases. As the control abutments were individualised, one-piece CAD/CAM titanium abutments were used. Clinical and radiographic parameters were assessed at abutment insertion and then on a yearly basis over the following 5 years.
Results: No significant differences in marginal bone level were observed between the titanium-base and one-piece abutments at any of the follow-up time points; however, when intragroup marginal bone levels were compared to the baseline values, significant differences were found at several follow-up time points. Intergroup differences were only found to be significant for pocket depth at the 4- (P = 0.006) and 5-year follow-ups (P = 0.024), favouring titanium-base abutments.
Conclusions: Within the limitations of the present study, it appears that the peri-implant tissues of this specific patient cohort responded to titanium-base abutments in a rather similar manner to one-piece abutments over a 5-year period; however, no definitive conclusions can be drawn due to the low power of the present study.