Fibre-optic, electronic pH test device compared with current NHS guidance to confirm nasogastric tube placement.

IF 3.3 Q2 NUTRITION & DIETETICS
Tracy Earley, Alison Young, Shirley Pringle, Yvonne Clarkson, Alexandra Williams, Rosemary Howell, Marcus Ineson
{"title":"Fibre-optic, electronic pH test device compared with current NHS guidance to confirm nasogastric tube placement.","authors":"Tracy Earley,&nbsp;Alison Young,&nbsp;Shirley Pringle,&nbsp;Yvonne Clarkson,&nbsp;Alexandra Williams,&nbsp;Rosemary Howell,&nbsp;Marcus Ineson","doi":"10.1136/bmjnph-2022-000506","DOIUrl":null,"url":null,"abstract":"<p><p>The clinical objectives of this prospective, random, convenience series were: 1. Compare a novel fibre-optic pH test device (NGPOD) to gastric aspirate and pH testing for nasogastric tube (NGT) confirmation. 2. Determine if the new device reduces the need for chest radiography (chest X-ray, CXR).</p><p><strong>Methods: </strong>Recruitment of patients over the age of 18, requiring NGT feeding.Exclusion criteria: oesophageal gastrointestinal surgery within 3 months; all those with partial or total gastrectomy; bleeding gastric and duodenal ulcers; gastric cancer; those with oesophageal varices; those considered to be inappropriate.The index test, NGPOD, comprises a fine, flexible fibre-optic sensor passed down the NGT, then connected to an electronic device. A green light indicates pH ≤5.5, and a red light if pH is >5.5.The reference test is withdrawal of gastric aspirate and testing with universal pH indicator strips then comparison to a colour chart. Second-line testing is establishing NGT position by CXR or subjective clinical assessment (SCA) in intensive care unit (ICU).</p><p><strong>Results: </strong>The analysed data set contained 174 subjects who had undergone 496 tests, 96 initial and 400 repeat NGT checks.For all patients, NGPOD can reduce the need for CXR or SCA by 21.2%.In ICU, NGPOD can reduce the need for CXR or SCA by 24.5%.When performing initial tests, immediately after tube placement, NGPOD can reduce the need for CXR or SCA in 61% of patients.With repeat testing, NGPOD can reduce the need to progress to CXR or SCA in 16% of tests.</p><p><strong>Conclusions: </strong>The objective, yes-no result delivered by NGPOD, eliminates the subjective reading of a pH strip colour change, reducing the subjective element. The index test has the opportunity to reduce risk, improve safety and decrease the numbers of patients requiring X-ray. It, therefore, has the potential to reduce never events associated with NGT misplacement.</p>","PeriodicalId":36307,"journal":{"name":"BMJ Nutrition, Prevention and Health","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9813617/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Nutrition, Prevention and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjnph-2022-000506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUTRITION & DIETETICS","Score":null,"Total":0}
引用次数: 2

Abstract

The clinical objectives of this prospective, random, convenience series were: 1. Compare a novel fibre-optic pH test device (NGPOD) to gastric aspirate and pH testing for nasogastric tube (NGT) confirmation. 2. Determine if the new device reduces the need for chest radiography (chest X-ray, CXR).

Methods: Recruitment of patients over the age of 18, requiring NGT feeding.Exclusion criteria: oesophageal gastrointestinal surgery within 3 months; all those with partial or total gastrectomy; bleeding gastric and duodenal ulcers; gastric cancer; those with oesophageal varices; those considered to be inappropriate.The index test, NGPOD, comprises a fine, flexible fibre-optic sensor passed down the NGT, then connected to an electronic device. A green light indicates pH ≤5.5, and a red light if pH is >5.5.The reference test is withdrawal of gastric aspirate and testing with universal pH indicator strips then comparison to a colour chart. Second-line testing is establishing NGT position by CXR or subjective clinical assessment (SCA) in intensive care unit (ICU).

Results: The analysed data set contained 174 subjects who had undergone 496 tests, 96 initial and 400 repeat NGT checks.For all patients, NGPOD can reduce the need for CXR or SCA by 21.2%.In ICU, NGPOD can reduce the need for CXR or SCA by 24.5%.When performing initial tests, immediately after tube placement, NGPOD can reduce the need for CXR or SCA in 61% of patients.With repeat testing, NGPOD can reduce the need to progress to CXR or SCA in 16% of tests.

Conclusions: The objective, yes-no result delivered by NGPOD, eliminates the subjective reading of a pH strip colour change, reducing the subjective element. The index test has the opportunity to reduce risk, improve safety and decrease the numbers of patients requiring X-ray. It, therefore, has the potential to reduce never events associated with NGT misplacement.

Abstract Image

光纤、电子pH试验装置与现行NHS指南进行比较,确认鼻胃管置入。
这项前瞻性、随机、方便的研究的临床目的是:1。比较一种新型光纤pH测试装置(NGPOD)与胃吸液和鼻胃管(NGT)确认的pH测试。2. 确定新设备是否减少了胸部x光检查(胸部x光,CXR)的需要。方法:招募年龄在18岁以上、需要NGT喂养的患者。排除标准:3个月内食管胃肠手术;全部或部分胃切除者;胃和十二指肠溃疡出血;胃癌;食管静脉曲张患者;被认为是不合适的。指数测试,NGPOD,包括一个精细的,柔性的光纤传感器,通过NGT,然后连接到一个电子设备。pH≤5.5时绿灯亮,>5.5时红灯亮。参考试验是抽出胃吸液,用通用pH指示剂条进行测试,然后与彩色图表进行比较。二线检测是在重症监护室(ICU)通过CXR或主观临床评估(SCA)确定NGT位置。结果:分析的数据集包含174名受试者,他们进行了496次测试,96次首次和400次重复NGT检查。对于所有患者,NGPOD可将CXR或SCA的需求减少21.2%。在ICU中,NGPOD可减少24.5%的CXR或SCA需求。在置管后立即进行初始测试时,NGPOD可以减少61%的患者对CXR或SCA的需求。通过重复测试,NGPOD可以在16%的测试中减少进展到CXR或SCA的需要。结论:NGPOD提供的客观,是-否结果消除了pH条颜色变化的主观读数,减少了主观因素。指数测试有机会降低风险,提高安全性并减少需要x光检查的患者数量。因此,它有可能减少与NGT错位相关的任何事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMJ Nutrition, Prevention and Health
BMJ Nutrition, Prevention and Health Nursing-Nutrition and Dietetics
CiteScore
5.80
自引率
0.00%
发文量
34
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信