Paul J Anderson, Christina M Wood-Wentz, Kent R Bailey, Bruce D Johnson
{"title":"Objective Versus Self-Reported Sleep Quality at High Altitude.","authors":"Paul J Anderson, Christina M Wood-Wentz, Kent R Bailey, Bruce D Johnson","doi":"10.1089/ham.2017.0078","DOIUrl":null,"url":null,"abstract":"<p><p>Anderson, Paul J., Christina M. Wood-Wentz, Kent R. Bailey, and Bruce D. Johnson. Objective versus self-reported sleep quality at high altitude. <i>High Alt Med Biol</i>. 24:144-148, 2023. <b><i>Background:</i></b> Previous studies have found little relationship between polysomnography and a diagnosis of acute mountain sickness (AMS) using the Lake Louise Symptom Questionnaire (LLSQ). The correlation between sleep question responses on the LLSQ and polysomnography results has not been explored. We compared LLSQ sleep responses and polysomnography data from our previous study of workers rapidly transported to the South Pole. <b><i>Methods:</i></b> Sixty-three subjects completed a 3-hour flight from sea level to the South Pole (3200 m, 9800 ft). Participants completed limited overnight polysomnography on their first night and completed LLSQ upon awakening. We compared polysomnography results at the South Pole with sleep question responses on the LLSQ to assess their degree of correspondence. <b><i>Results:</i></b> Twenty-two (30%) individuals reported no sleep problems whereas 20 (32%) reported some problems and 20 (33%) individuals reported poor sleep and 1 reported no sleep (<i>n</i> = 1). Median sleep efficiency was (94%) among response groups and mean overnight oxygen saturation was 81%. Median apnea hypopnea index (AHI; events/hour) was 10.2 in those who reported no problems sleeping, 5.1 in those reporting some problems sleeping, and 13.7 in those who reported poor sleep. These differences were not statistically significant. <b><i>Conclusion:</i></b> Self-reported sleep quality varied but there were no associated significant differences in sleep efficiency, overnight oxygen saturation, nor AHI. Studies that explore the role of objective sleep quality in the development of AMS should remove the sleep question on the LLSQ from AMS scoring algorithms.</p>","PeriodicalId":12975,"journal":{"name":"High altitude medicine & biology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/ham.2017.0078","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High altitude medicine & biology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/ham.2017.0078","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 7
Abstract
Anderson, Paul J., Christina M. Wood-Wentz, Kent R. Bailey, and Bruce D. Johnson. Objective versus self-reported sleep quality at high altitude. High Alt Med Biol. 24:144-148, 2023. Background: Previous studies have found little relationship between polysomnography and a diagnosis of acute mountain sickness (AMS) using the Lake Louise Symptom Questionnaire (LLSQ). The correlation between sleep question responses on the LLSQ and polysomnography results has not been explored. We compared LLSQ sleep responses and polysomnography data from our previous study of workers rapidly transported to the South Pole. Methods: Sixty-three subjects completed a 3-hour flight from sea level to the South Pole (3200 m, 9800 ft). Participants completed limited overnight polysomnography on their first night and completed LLSQ upon awakening. We compared polysomnography results at the South Pole with sleep question responses on the LLSQ to assess their degree of correspondence. Results: Twenty-two (30%) individuals reported no sleep problems whereas 20 (32%) reported some problems and 20 (33%) individuals reported poor sleep and 1 reported no sleep (n = 1). Median sleep efficiency was (94%) among response groups and mean overnight oxygen saturation was 81%. Median apnea hypopnea index (AHI; events/hour) was 10.2 in those who reported no problems sleeping, 5.1 in those reporting some problems sleeping, and 13.7 in those who reported poor sleep. These differences were not statistically significant. Conclusion: Self-reported sleep quality varied but there were no associated significant differences in sleep efficiency, overnight oxygen saturation, nor AHI. Studies that explore the role of objective sleep quality in the development of AMS should remove the sleep question on the LLSQ from AMS scoring algorithms.
期刊介绍:
High Altitude Medicine & Biology is the only peer-reviewed journal covering the medical and biological issues that impact human life at high altitudes. The Journal delivers critical findings on the impact of high altitude on lung and heart disease, appetite and weight loss, pulmonary and cerebral edema, hypertension, dehydration, infertility, and other diseases. It covers the full spectrum of high altitude life sciences from pathology to human and animal ecology.