Magnesium Bioresorbable Scaffold (BRS) Magmaris vs Biodegradable Polymer DES Ultimaster in NSTE-ACS Population—12-Month Clinical Outcome

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Piotr Rola, Adrian Włodarczak, Szymon Włodarczak, Mateusz Barycki, Marek Szudrowicz, Magdalena Łanocha, Łukasz Furtan, Katarzyna Woźnica, Jan Jakub Kulczycki, Joanna Jaroszewska-Pozorska, Michalina Kędzierska, Adrian Doroszko, Maciej Lesiak
{"title":"Magnesium Bioresorbable Scaffold (BRS) Magmaris vs Biodegradable Polymer DES Ultimaster in NSTE-ACS Population—12-Month Clinical Outcome","authors":"Piotr Rola,&nbsp;Adrian Włodarczak,&nbsp;Szymon Włodarczak,&nbsp;Mateusz Barycki,&nbsp;Marek Szudrowicz,&nbsp;Magdalena Łanocha,&nbsp;Łukasz Furtan,&nbsp;Katarzyna Woźnica,&nbsp;Jan Jakub Kulczycki,&nbsp;Joanna Jaroszewska-Pozorska,&nbsp;Michalina Kędzierska,&nbsp;Adrian Doroszko,&nbsp;Maciej Lesiak","doi":"10.1155/2022/5223317","DOIUrl":null,"url":null,"abstract":"<div>\n <p><i>Background</i>. Percutaneous coronary intervention (PCI) in the acute coronary syndrome (ACS) setting is associated with a greater probability of device failure. The currently ongoing development of new scaffold technologies has concentrated an effort on improving the PCI outcomes, including the use of new biodegradable materials. This pilot study evaluates the performance of a magnesium bioresorbable scaffold (Magmaris, Biotronik, Germany) in comparison to the sirolimus-eluting bioresorbable polymer stents (BP-SES) (Ultimaster, Terumo, Japan) in the NSTE-ACS setting. <i>Methods</i>. The population of this pilot comprised 362 patients assigned to one of two arms (193-Magmaris vs 169-Ultimaster). The data regarding the primary outcome comprised of death from cardiac causes, myocardial infarction, and stent thrombosis, along with target-lesion failure (TLF) and other clinical events was collected in the 1-yearfollow-up. <i>Results</i>. There were no statistically significant differences in clinical outcomes in the short term (30 days) or in the 1-yearfollow-up between both groups. <i>Conclusion</i>. At 12 months, there were no statistically significant differences between the Magmaris and Ultimaster for composed endpoints or the TLF.</p>\n </div>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2022 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2022-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9794423/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2022/5223317","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Percutaneous coronary intervention (PCI) in the acute coronary syndrome (ACS) setting is associated with a greater probability of device failure. The currently ongoing development of new scaffold technologies has concentrated an effort on improving the PCI outcomes, including the use of new biodegradable materials. This pilot study evaluates the performance of a magnesium bioresorbable scaffold (Magmaris, Biotronik, Germany) in comparison to the sirolimus-eluting bioresorbable polymer stents (BP-SES) (Ultimaster, Terumo, Japan) in the NSTE-ACS setting. Methods. The population of this pilot comprised 362 patients assigned to one of two arms (193-Magmaris vs 169-Ultimaster). The data regarding the primary outcome comprised of death from cardiac causes, myocardial infarction, and stent thrombosis, along with target-lesion failure (TLF) and other clinical events was collected in the 1-yearfollow-up. Results. There were no statistically significant differences in clinical outcomes in the short term (30 days) or in the 1-yearfollow-up between both groups. Conclusion. At 12 months, there were no statistically significant differences between the Magmaris and Ultimaster for composed endpoints or the TLF.

Abstract Image

镁生物可吸收支架(BRS) Magmaris与生物可降解聚合物DES Ultimaster在NSTE-ACS人群中的12个月临床结果
背景:急性冠脉综合征(ACS)患者的经皮冠状动脉介入治疗(PCI)与器械失效的可能性较大相关。目前正在进行的新支架技术的发展集中在改善PCI结果上,包括使用新的可生物降解材料。本初步研究评估了在NSTE-ACS环境下,镁生物可吸收支架(Magmaris, Biotronik,德国)与西罗莫司洗脱生物可吸收聚合物支架(BP-SES) (Ultimaster, Terumo,日本)的性能。方法:该试验人群包括362名患者,分为两组(193-Magmaris vs 169-Ultimaster)。在1年的随访中收集了主要结局数据,包括心脏原因死亡、心肌梗死和支架血栓形成,以及靶病变失败(TLF)和其他临床事件。结果:两组患者短期(30天)和1年随访的临床结果比较,差异均无统计学意义。结论:在12个月时,Magmaris和Ultimaster在组成终点或TLF方面无统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信