Field output correction factors of stereotactic cones for a diode detector: Dependence on cone size, measurement setup, reference field size and photon energy.

IF 0.7 Q4 SURGERY
Journal of radiosurgery and SBRT Pub Date : 2022-01-01
Yongsook C Lee, Yongbok Kim
{"title":"Field output correction factors of stereotactic cones for a diode detector: Dependence on cone size, measurement setup, reference field size and photon energy.","authors":"Yongsook C Lee,&nbsp;Yongbok Kim","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated if field output correction factors (FOCFs) of Varian stereotactic cones for Edge detectorTM had dependence on cone size, measurement setup, reference field size and/or photon energy. Field output factors (FOFs) of stereotactic cones were measured at three depths (1.5 cm, 5 cm and 10 cm) in two different setups (source-to-surface distance (SSD) and source-to-axis distance (SAD)) with two photon energies (6 MV and 6 MV flattening filter free) using the Edge detector and Exradin<sub>®</sub> W2 scintillator. Two reference fields (10 × 10 cm<sup>2</sup> and 4 × 4 cm<sup>2</sup>) were chosen. FOCFs for the Edge detector were determined by calculating FOF<sub>W2</sub>/FOF<sub>Edge</sub> and compared among cones and between depths, setups, reference fields and energies. It is concluded that FOCFs for the Edge detector have dependence on cone size, SSD/SAD setup and energy for small cones, but do not have dependence on depth and reference field size.</p>","PeriodicalId":16917,"journal":{"name":"Journal of radiosurgery and SBRT","volume":"8 2","pages":"127-136"},"PeriodicalIF":0.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9489070/pdf/rsbrt-8-127.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of radiosurgery and SBRT","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated if field output correction factors (FOCFs) of Varian stereotactic cones for Edge detectorTM had dependence on cone size, measurement setup, reference field size and/or photon energy. Field output factors (FOFs) of stereotactic cones were measured at three depths (1.5 cm, 5 cm and 10 cm) in two different setups (source-to-surface distance (SSD) and source-to-axis distance (SAD)) with two photon energies (6 MV and 6 MV flattening filter free) using the Edge detector and Exradin® W2 scintillator. Two reference fields (10 × 10 cm2 and 4 × 4 cm2) were chosen. FOCFs for the Edge detector were determined by calculating FOFW2/FOFEdge and compared among cones and between depths, setups, reference fields and energies. It is concluded that FOCFs for the Edge detector have dependence on cone size, SSD/SAD setup and energy for small cones, but do not have dependence on depth and reference field size.

Abstract Image

二极管探测器立体定向锥的场输出校正因子:依赖于锥尺寸,测量装置,参考场尺寸和光子能量。
本文研究了用于边缘检测器的瓦里安立体定向锥的场输出校正因子(focf)是否与锥尺寸、测量装置、参考场尺寸和/或光子能量有关。利用Edge检测器和Exradin®W2闪烁体,在三种深度(1.5 cm、5 cm和10 cm)下,以两种不同的设置(源-表面距离(SSD)和源-轴距离(SAD))测量了两种光子能量(6 MV和6 MV无压平滤波器)下立体定向锥的场输出因子(FOFs)。选取10 × 10 cm2和4 × 4 cm2两个参考场。通过计算FOFW2/FOFEdge来确定边缘检测器的focf,并对锥体之间以及深度、设置、参考场和能量之间进行比较。结果表明,边缘检测器的focf与锥体尺寸、SSD/SAD设置和小锥体的能量有关,而与深度和参考视场尺寸无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
8.30%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信