An efficient method for simultaneous detection of Pheniramine, Pentazocine and cotinine in urine by Gas Chromatography in De-addiction program.

Raka Jain, Shayani Ghosh, Nizamuddin Saifi
{"title":"An efficient method for simultaneous detection of Pheniramine, Pentazocine and cotinine in urine by Gas Chromatography in De-addiction program.","authors":"Raka Jain,&nbsp;Shayani Ghosh,&nbsp;Nizamuddin Saifi","doi":"10.22122/AHJ.2022.196722.1179","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nonmedical use of prescription drugs for recreational purposes is a major health problem that raises high concerns for public health. Recently, several laboratory studies have reported the misuse of pentazocine, an agonist-antagonist opioid in combination with antihistamines in opioid addicts. Illicit self-administration of prescription drugs has been increasingly reported in India. Urinalysis as an adjunct to self-report plays a key role in providing additional information in the treatment of drug users. This paper aims to discuss a simple, convenient, and rapid capillary column gas-liquid chromatography method for simultaneous detection of pentazocine, pheniramine, and cotinine in urine.</p><p><strong>Methods: </strong>The sample was extracted with chloroform and isopropanol (3:1,v/v) and evaporated to dryness. After reconstitution with methanol, it was directly subjected to gas chromatography analysis. Method performance was evaluated and validated in terms of sensitivity, precision, the limit of detection (LOD), and the limit of quantification (LOQ).</p><p><strong>Findings: </strong>The linearity obtained was in the range of 50-1000 ng/ml with a correlation coefficient (r) above 0.999 for each drug. Good LOQ (50ng/ml) was obtained with each drug. Also, the developed method was effective in analyzing samples from patients with suspected abuse of these drugs.</p><p><strong>Conclusion: </strong>The technique was found to be simple, robust, sensitive, and precise in the simultaneous analysis of drugs (pentazocine, pheniramine, and cotinine). This method was proved to be useful and cost-effective in treating and monitoring patients seeking help for addiction in clinical settings.</p>","PeriodicalId":33943,"journal":{"name":"Addiction and Health","volume":"14 2","pages":"96-104"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/10/60/ahj-14-96.PMC9743812.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Addiction and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22122/AHJ.2022.196722.1179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Nonmedical use of prescription drugs for recreational purposes is a major health problem that raises high concerns for public health. Recently, several laboratory studies have reported the misuse of pentazocine, an agonist-antagonist opioid in combination with antihistamines in opioid addicts. Illicit self-administration of prescription drugs has been increasingly reported in India. Urinalysis as an adjunct to self-report plays a key role in providing additional information in the treatment of drug users. This paper aims to discuss a simple, convenient, and rapid capillary column gas-liquid chromatography method for simultaneous detection of pentazocine, pheniramine, and cotinine in urine.

Methods: The sample was extracted with chloroform and isopropanol (3:1,v/v) and evaporated to dryness. After reconstitution with methanol, it was directly subjected to gas chromatography analysis. Method performance was evaluated and validated in terms of sensitivity, precision, the limit of detection (LOD), and the limit of quantification (LOQ).

Findings: The linearity obtained was in the range of 50-1000 ng/ml with a correlation coefficient (r) above 0.999 for each drug. Good LOQ (50ng/ml) was obtained with each drug. Also, the developed method was effective in analyzing samples from patients with suspected abuse of these drugs.

Conclusion: The technique was found to be simple, robust, sensitive, and precise in the simultaneous analysis of drugs (pentazocine, pheniramine, and cotinine). This method was proved to be useful and cost-effective in treating and monitoring patients seeking help for addiction in clinical settings.

Abstract Image

Abstract Image

Abstract Image

气相色谱法同时检测尿中苯那敏、戊唑嗪和可替宁的方法。
背景:以娱乐为目的非医疗使用处方药是引起公众高度关注的一个主要健康问题。最近,一些实验室研究报告了阿片类药物成瘾者滥用戊唑嗪(一种阿片类药物激动剂-拮抗剂)与抗组胺药的情况。在印度,非法自行服用处方药的报道越来越多。尿检作为自我报告的辅助手段,在为吸毒者治疗提供额外信息方面发挥着关键作用。本文旨在探讨一种简便、快速的毛细管柱气液色谱法同时检测尿液中戊唑嗪、苯那敏和可替宁的方法。方法:用氯仿和异丙醇(3:1,v/v)萃取,蒸发干燥。用甲醇重整后,直接进行气相色谱分析。从灵敏度、精密度、检出限(LOD)和定量限(LOQ)等方面对方法性能进行评价和验证。结果:各药物的线性范围为50 ~ 1000 ng/ml,相关系数(r)均大于0.999。各药物的定量限均为50ng/ml。此外,所开发的方法在分析疑似滥用这些药物的患者样本方面是有效的。结论:该方法简便、可靠、灵敏、准确,可用于戊唑嗪、苯那敏和可替宁的同时分析。这种方法被证明是有用的和具有成本效益的治疗和监测患者寻求帮助成瘾在临床设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
3
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信