Hüseyin Şahin Uysal, Alex Ojeda-Aravena, Mehmet Ulaş, Eduardo Báez-San Martín, Rodrigo Ramirez-Campillo
{"title":"Validity, Reliability, and Sensitivity of Mobile Applications to Assess Change of Direction Speed.","authors":"Hüseyin Şahin Uysal, Alex Ojeda-Aravena, Mehmet Ulaş, Eduardo Báez-San Martín, Rodrigo Ramirez-Campillo","doi":"10.5114/jhk/167465","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to assess the validity, reliability, and sensitivity of mobile applications for assessing change-of-direction speed (CODS) performance. Thirty college athletes performed two Illinois CODS tests during one session. Assessments were carried out simultaneously using six devices (the CODTimer app, Seconds Count app, StopwatchCamera app, two analog stopwatches, and timing gates). Validity analyses included Pearson's product-moment correlation analysis, a linear regression model, and Bland-Altman plots. Reliability analyses included the intraclass correlation coefficient (ICC), the coefficient of variation (CV%), and the paired-sample t test. Sensitivity analyses included the typical error and smallest worthwhile change (SWC). The results showed that validity, reliability, and sensitivity values were higher for the CODTimer app (r = 0.99, R<sup>2</sup> = 0.99, mean bias = -0.03 ± 0.10, CV% = 3.21, ICC = 0.89, SWC rating: good, p = 0.84) and the Seconds Count app (r = 0.99, R<sup>2</sup> = 0.99, mean bias = -0.03 ± 0.08, CV% = 3.28, ICC = 0.88, SWC rating: good, p = 0.84) relative to the StopwatchCamera app (r = 0.98, R<sup>2</sup> = 0.97, mean bias = -0.11 ± 0.22, CV% = 3.43, ICC = 0.86, SWC rating: marginal, p = 0.10), Analog Stopwatch 1 (r = 0.98, R<sup>2</sup> = 0.96, mean bias = -0.09 ± 0.42, CV% = 2.95, ICC = 0.90, SWC rating: good, p = 0.91), and Analog Stopwatch 2 (r = 0.99, R<sup>2</sup> = 0.97, mean bias = -0.12 ± 0.88, CV% = 3.51, ICC = 0.87, SWC rating: marginal, p = 0.96). In conclusion, compared to timing gates, the CODTimer app and Seconds Count app provided lower measurement bias and higher sensitivity for assessing CODS performance.</p>","PeriodicalId":16055,"journal":{"name":"Journal of Human Kinetics","volume":"87 ","pages":"217-228"},"PeriodicalIF":1.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10407321/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Human Kinetics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5114/jhk/167465","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to assess the validity, reliability, and sensitivity of mobile applications for assessing change-of-direction speed (CODS) performance. Thirty college athletes performed two Illinois CODS tests during one session. Assessments were carried out simultaneously using six devices (the CODTimer app, Seconds Count app, StopwatchCamera app, two analog stopwatches, and timing gates). Validity analyses included Pearson's product-moment correlation analysis, a linear regression model, and Bland-Altman plots. Reliability analyses included the intraclass correlation coefficient (ICC), the coefficient of variation (CV%), and the paired-sample t test. Sensitivity analyses included the typical error and smallest worthwhile change (SWC). The results showed that validity, reliability, and sensitivity values were higher for the CODTimer app (r = 0.99, R2 = 0.99, mean bias = -0.03 ± 0.10, CV% = 3.21, ICC = 0.89, SWC rating: good, p = 0.84) and the Seconds Count app (r = 0.99, R2 = 0.99, mean bias = -0.03 ± 0.08, CV% = 3.28, ICC = 0.88, SWC rating: good, p = 0.84) relative to the StopwatchCamera app (r = 0.98, R2 = 0.97, mean bias = -0.11 ± 0.22, CV% = 3.43, ICC = 0.86, SWC rating: marginal, p = 0.10), Analog Stopwatch 1 (r = 0.98, R2 = 0.96, mean bias = -0.09 ± 0.42, CV% = 2.95, ICC = 0.90, SWC rating: good, p = 0.91), and Analog Stopwatch 2 (r = 0.99, R2 = 0.97, mean bias = -0.12 ± 0.88, CV% = 3.51, ICC = 0.87, SWC rating: marginal, p = 0.96). In conclusion, compared to timing gates, the CODTimer app and Seconds Count app provided lower measurement bias and higher sensitivity for assessing CODS performance.
期刊介绍:
The Journal of Human Kinetics is an open access interdisciplinary periodical offering the latest research in the science of human movement studies. This comprehensive professional journal features articles and research notes encompassing such topic areas as: Kinesiology, Exercise Physiology and Nutrition, Sports Training and Behavioural Sciences in Sport, but especially considering elite and competitive aspects of sport.
The journal publishes original papers, invited reviews, short communications and letters to the Editors. Manuscripts submitted to the journal must contain novel data on theoretical or experimental research or on practical applications in the field of sport sciences.
The Journal of Human Kinetics is published in March, June, September and December.