Diagnostic Accuracy of Vibration Controlled Transient Elastography as Non-invasive Assessment of Liver Fibrosis in Patients with Non-alcoholic Fatty Liver Disease.

Q3 Medicine
Hossain Salehi, Amir Mohammad Salehi, Mohammad Ebrahim Ghamarchehreh, Elham Khanlarzadeh, Masoud Reza Sohrabi
{"title":"Diagnostic Accuracy of Vibration Controlled Transient Elastography as Non-invasive Assessment of Liver Fibrosis in Patients with Non-alcoholic Fatty Liver Disease.","authors":"Hossain Salehi,&nbsp;Amir Mohammad Salehi,&nbsp;Mohammad Ebrahim Ghamarchehreh,&nbsp;Elham Khanlarzadeh,&nbsp;Masoud Reza Sohrabi","doi":"10.34172/mejdd.2023.316","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Liver biopsy remain as the gold standard for diagnosing hepatic fibrosis; however, it has some limitations, such as life-threatening complications, low acceptance by the patients, and variations in the related sample. Therefore, there is a need for the development of non-invasive investigations for diagnosing hepatic fibrosis. Vibration-controlled transient elastography (VCTE) is one of these non-invasive methods. <b>Methods:</b> This study included 73 patients suffering from non-alcoholic fatty liver disease (NAFLD) who were older than 18 years. The patients underwent VCTE at the Baqiatallah and Firoozgar hospitals. Then, they underwent a liver biopsy by an experienced radiologist in the same hospital. A receiver operating characteristic (ROC) curve of different fibrosis stages was used to evaluate the VCTE verification. <b>Results:</b> VCTE could detect any fibrosis levels (stage 1 and higher) with an area under the ROC curve (AUROC) of 0.381. Moreover, it detected stage 2-4 fibrosis with an AUROC of 0.400, stage 3-4 fibrosis with an AUROC of 0.687, and stage 4 fibrosis with an AUROC of 0.984. <b>Conclusion:</b> The VCTE has high clinical validity in diagnosing the advanced stages of fibrosis (stages 3, 4) and can be a suitable alternative to the invasive method of liver biopsy with high reliability.</p>","PeriodicalId":18517,"journal":{"name":"Middle East Journal of Digestive Diseases","volume":"15 1","pages":"26-31"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/37/91/mejdd-15-26.PMC10404076.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Middle East Journal of Digestive Diseases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/mejdd.2023.316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Liver biopsy remain as the gold standard for diagnosing hepatic fibrosis; however, it has some limitations, such as life-threatening complications, low acceptance by the patients, and variations in the related sample. Therefore, there is a need for the development of non-invasive investigations for diagnosing hepatic fibrosis. Vibration-controlled transient elastography (VCTE) is one of these non-invasive methods. Methods: This study included 73 patients suffering from non-alcoholic fatty liver disease (NAFLD) who were older than 18 years. The patients underwent VCTE at the Baqiatallah and Firoozgar hospitals. Then, they underwent a liver biopsy by an experienced radiologist in the same hospital. A receiver operating characteristic (ROC) curve of different fibrosis stages was used to evaluate the VCTE verification. Results: VCTE could detect any fibrosis levels (stage 1 and higher) with an area under the ROC curve (AUROC) of 0.381. Moreover, it detected stage 2-4 fibrosis with an AUROC of 0.400, stage 3-4 fibrosis with an AUROC of 0.687, and stage 4 fibrosis with an AUROC of 0.984. Conclusion: The VCTE has high clinical validity in diagnosing the advanced stages of fibrosis (stages 3, 4) and can be a suitable alternative to the invasive method of liver biopsy with high reliability.

振动控制瞬时弹性成像对非酒精性脂肪性肝病患者肝纤维化的诊断准确性
背景:肝活检仍然是诊断肝纤维化的金标准;然而,它也有一些局限性,如危及生命的并发症,患者的接受度低,以及相关样本的差异。因此,有必要发展诊断肝纤维化的非侵入性检查。振动控制瞬态弹性成像(VCTE)就是其中一种非侵入性方法。方法:本研究纳入73例年龄大于18岁的非酒精性脂肪性肝病(NAFLD)患者。患者在Baqiatallah和Firoozgar医院接受了VCTE治疗。然后,他们在同一家医院接受了一位经验丰富的放射科医生的肝脏活检。采用不同纤维化分期的受试者工作特征(ROC)曲线评价VCTE的有效性。结果:VCTE可以检测到任何纤维化水平(1期及以上),ROC曲线下面积(AUROC)为0.381。此外,它检测到2-4期纤维化的AUROC为0.400,3-4期纤维化的AUROC为0.687,4期纤维化的AUROC为0.984。结论:VCTE诊断晚期肝纤维化(3、4期)具有较高的临床有效性,可作为有创肝活检的替代方法,可靠性高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Middle East Journal of Digestive Diseases
Middle East Journal of Digestive Diseases Medicine-Gastroenterology
CiteScore
1.20
自引率
0.00%
发文量
33
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信