The Acute Effects of Theragun™ Percussive Therapy on Viscoelastic Tissue Dynamics and Hamstring Group Range of Motion.

IF 2.4 2区 医学 Q2 SPORT SCIENCES
Brendon Skinner, Lauren Dunn, Richard Moss
{"title":"The Acute Effects of Theragun™ Percussive Therapy on Viscoelastic Tissue Dynamics and Hamstring Group Range of Motion.","authors":"Brendon Skinner,&nbsp;Lauren Dunn,&nbsp;Richard Moss","doi":"10.52082/jssm.2023.496","DOIUrl":null,"url":null,"abstract":"<p><p>Handheld percussive therapy (PT) massage guns have seen a rapid rise in use and with-it increased attention within injury prevention and sport performance settings. Early studies have proposed beneficial effects upon range of motion (ROM), however the mechanism behind these increases remains unreported. This study aimed to determine the influence of a minimal frequency PT dose upon ROM and myotonometry outcomes. Twenty participants (N = 20; 13 males and 7 females, height 1.78cm ± 9.62; weight 77.35kg ± 8.46) participants were allocated to either a PT group receiving 2 x 60-seconds (plus 30-seconds rest) via a Theragun™ Pro4 to the hamstrings covering a standardised 20 lengths from proximal to distal via the standard ball attachment at 1 bar of pressure or a control group (CON) of 2-minutes 30-seconds passive supine rest. Pre and post intervention outcomes were measured for ROM via passive straight leg raise (PSLR) and tissue dynamics via MyotonPro (Tone, Stiffness, Elasticity, Relaxation Time). Results showed significant within-group increases (p < 0.0001, ηp<sup>2</sup> 0.656, +11.4%) in ROM following PT and between group difference against CON (P < 0.026). Significant within-group differences in stiffness (p < 0.016, ηp<sup>2</sup> 0.144, -6%), tone (p < 0.003, ηp<sup>2</sup> 0.213, +2%) and relaxation time (p < 0.002, ηp<sup>2</sup> 0.232, +6.3%) were also reported following PT. No significant difference was reported in elasticity (P > 0.05) or any other between group outcomes. PT therapy can provide an acute increase in hamstring group ROM following a resultant decrease in tissue stiffness.</p>","PeriodicalId":54765,"journal":{"name":"Journal of Sports Science and Medicine","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10499144/pdf/jssm-22-496.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sports Science and Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.52082/jssm.2023.496","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Handheld percussive therapy (PT) massage guns have seen a rapid rise in use and with-it increased attention within injury prevention and sport performance settings. Early studies have proposed beneficial effects upon range of motion (ROM), however the mechanism behind these increases remains unreported. This study aimed to determine the influence of a minimal frequency PT dose upon ROM and myotonometry outcomes. Twenty participants (N = 20; 13 males and 7 females, height 1.78cm ± 9.62; weight 77.35kg ± 8.46) participants were allocated to either a PT group receiving 2 x 60-seconds (plus 30-seconds rest) via a Theragun™ Pro4 to the hamstrings covering a standardised 20 lengths from proximal to distal via the standard ball attachment at 1 bar of pressure or a control group (CON) of 2-minutes 30-seconds passive supine rest. Pre and post intervention outcomes were measured for ROM via passive straight leg raise (PSLR) and tissue dynamics via MyotonPro (Tone, Stiffness, Elasticity, Relaxation Time). Results showed significant within-group increases (p < 0.0001, ηp2 0.656, +11.4%) in ROM following PT and between group difference against CON (P < 0.026). Significant within-group differences in stiffness (p < 0.016, ηp2 0.144, -6%), tone (p < 0.003, ηp2 0.213, +2%) and relaxation time (p < 0.002, ηp2 0.232, +6.3%) were also reported following PT. No significant difference was reported in elasticity (P > 0.05) or any other between group outcomes. PT therapy can provide an acute increase in hamstring group ROM following a resultant decrease in tissue stiffness.

Theragun™冲击疗法对粘弹性组织动力学和腿筋运动范围的急性影响。
手持式冲击疗法(PT)按摩枪的使用迅速增加,并在伤害预防和运动表现设置中引起越来越多的关注。早期的研究提出了对活动范围(ROM)有益的影响,但这些增加背后的机制仍未报道。本研究旨在确定最小频率PT剂量对ROM和肌测结果的影响。20名受试者(N = 20;男13名,女7名,身高1.78cm±9.62;体重77.35kg±8.46)的参与者被分配到PT组,通过Theragun™Pro4在1 bar压力下通过标准球连接从近端到远端覆盖标准化20个长度的腘绳肌,接受2 x 60秒(加30秒休息),或对照组(CON)接受2分钟30秒被动仰卧休息。通过被动直腿抬高(PSLR)测量干预前和干预后的ROM结果,通过MyotonPro测量组织动力学(张力、刚度、弹性、松弛时间)。结果显示,PT后ROM组内升高(p < 0.0001, ηp2 0.656, +11.4%),组间与CON比较差异有统计学意义(p < 0.026)。治疗后组内硬度(p < 0.016, ηp2 0.144, -6%)、张力(p < 0.003, ηp2 0.213, +2%)和松弛时间(p < 0.002, ηp2 0.232, +6.3%)也有显著差异。弹性(p > 0.05)或其他任何组间结果均无显著差异。PT治疗可提供腘绳肌组ROM的急性增加,随之而来的是组织硬度的降低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.60
自引率
6.20%
发文量
56
审稿时长
4-8 weeks
期刊介绍: The Journal of Sports Science and Medicine (JSSM) is a non-profit making scientific electronic journal, publishing research and review articles, together with case studies, in the fields of sports medicine and the exercise sciences. JSSM is published quarterly in March, June, September and December. JSSM also publishes editorials, a "letter to the editor" section, abstracts from international and national congresses, panel meetings, conferences and symposia, and can function as an open discussion forum on significant issues of current interest.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信