Vandana Nagpal, Marcey L Osgood, Jennifer Reidy, Rose Healy, Brian Silver
{"title":"Improving Access to Specialist Palliative Care for Patients With Catastrophic Strokes Using Best Practice Advisory- a Feasibility Study.","authors":"Vandana Nagpal, Marcey L Osgood, Jennifer Reidy, Rose Healy, Brian Silver","doi":"10.1177/19418744231166265","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>The American Heart Association and American Stroke Association (AHA/ASA) strongly recommend specialty palliative care (PC) for all patients hospitalized with life-threatening or life-altering strokes to provide expert symptom management, improve communication, promote shared decision-making and relieve suffering. We piloted an intervention to remind physicians about high PC needs of their patients admitted with catastrophic stroke.</p><p><strong>Methods: </strong>We worked with colleagues from medical informatics to create a \"Best Practice Advisory\" (BPA) to recommend a goals-of-care conversation and PC consultation for patients with a National Institutes of Health Stroke Scale (NIHSS) score of 20 or more in our electronic medical record (Epic). We evaluated the impact of this BPA, after implementation, on the number and timing of PC consults and reviewed barriers to this system change.</p><p><strong>Results: </strong>The BPA was operational in Jan 2019. Data analysis showed that it fired for all patients with an entered NIHSS score of ≥20. Though a large portion of the BPAs (more than 90%) were acknowledged without documented reason (after selecting \"do not order\"), PC consultations per 100 patients with triggered BPA increased from the first year of implementation (11.7 in 2019) to the next 2 years (20.7 in 2020, 15.6 in 2021). Also, the providers learned to manage BPA alerts better resulting in more than 30% reduction in the number of BPA alerts fired for each patient encounter in 2020-2021 compared to 2019.</p>","PeriodicalId":46355,"journal":{"name":"Neurohospitalist","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10334048/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurohospitalist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19418744231166265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/12 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and purpose: The American Heart Association and American Stroke Association (AHA/ASA) strongly recommend specialty palliative care (PC) for all patients hospitalized with life-threatening or life-altering strokes to provide expert symptom management, improve communication, promote shared decision-making and relieve suffering. We piloted an intervention to remind physicians about high PC needs of their patients admitted with catastrophic stroke.
Methods: We worked with colleagues from medical informatics to create a "Best Practice Advisory" (BPA) to recommend a goals-of-care conversation and PC consultation for patients with a National Institutes of Health Stroke Scale (NIHSS) score of 20 or more in our electronic medical record (Epic). We evaluated the impact of this BPA, after implementation, on the number and timing of PC consults and reviewed barriers to this system change.
Results: The BPA was operational in Jan 2019. Data analysis showed that it fired for all patients with an entered NIHSS score of ≥20. Though a large portion of the BPAs (more than 90%) were acknowledged without documented reason (after selecting "do not order"), PC consultations per 100 patients with triggered BPA increased from the first year of implementation (11.7 in 2019) to the next 2 years (20.7 in 2020, 15.6 in 2021). Also, the providers learned to manage BPA alerts better resulting in more than 30% reduction in the number of BPA alerts fired for each patient encounter in 2020-2021 compared to 2019.