R Bloomquist, V Villalobos, C Patel, J Olson, F Rueggeberg
{"title":"Effect of RMGI Roughness and Dentin Bonding Primer on Shear Bond Strength of Sandwich-type Restorations.","authors":"R Bloomquist, V Villalobos, C Patel, J Olson, F Rueggeberg","doi":"10.2341/22-130-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The open sandwich technique is a reliable alternative to amalgam placement in deep proximal box preparations, where proper isolation and enamel bonding may not be possible. It is often difficult to prepare the box for composite placement without affecting the resin-modified glass ionomer (RMGI) that has been placed in the gingival portion. We hypothesized that RMGI surfaces that are roughened or those that use all steps in the manufacturing bonding protocol, including the priming solution, applied before placing a bonded composite increment, would have greater composite/RMGI shear bond strength.</p><p><strong>Design and methods: </strong>Shear bond strengths (SBS) of RMGI tested in the presence and absence of SiC roughening and primer-coating were tested using a fourth-generation dentin bonding agent to composite after thermocycling. Twenty specimens for four test conditions were fabricated and investigated. Data were subjected to a two-way ANOVA and the Holm-Sidak post-hoc test.</p><p><strong>Results: </strong>Placing dentin primer on unabraded RMGI provided a statistically significant improvement in SBS, but only modestly. Furthermore, because bond failure consistently occurred within the RMGI itself, none of the surface modifications have a clinically relevant impact on SBS at the RMGI to the composite interface.</p><p><strong>Conclusions: </strong>Clinicians should be aware that they need not avoid RMGI abrasion and do not need to incorporate all components of a fourth-generation bonding system when covering an RMGI sandwich layer with composite.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/22-130-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The open sandwich technique is a reliable alternative to amalgam placement in deep proximal box preparations, where proper isolation and enamel bonding may not be possible. It is often difficult to prepare the box for composite placement without affecting the resin-modified glass ionomer (RMGI) that has been placed in the gingival portion. We hypothesized that RMGI surfaces that are roughened or those that use all steps in the manufacturing bonding protocol, including the priming solution, applied before placing a bonded composite increment, would have greater composite/RMGI shear bond strength.
Design and methods: Shear bond strengths (SBS) of RMGI tested in the presence and absence of SiC roughening and primer-coating were tested using a fourth-generation dentin bonding agent to composite after thermocycling. Twenty specimens for four test conditions were fabricated and investigated. Data were subjected to a two-way ANOVA and the Holm-Sidak post-hoc test.
Results: Placing dentin primer on unabraded RMGI provided a statistically significant improvement in SBS, but only modestly. Furthermore, because bond failure consistently occurred within the RMGI itself, none of the surface modifications have a clinically relevant impact on SBS at the RMGI to the composite interface.
Conclusions: Clinicians should be aware that they need not avoid RMGI abrasion and do not need to incorporate all components of a fourth-generation bonding system when covering an RMGI sandwich layer with composite.
期刊介绍:
Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts.
One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use.