M V Raghav, A Geetha, V S Purushotham, K Mamatha, J Rajesh, Rajeev Raghuvanshi, Vivekananda Kalaiselvan, Shatrunjay Shukla, V Hariharan, B Naveen Gowda
{"title":"A cross sectional analysis of medical device associated adverse events with radiotherapy devices - A materiovigilance study.","authors":"M V Raghav, A Geetha, V S Purushotham, K Mamatha, J Rajesh, Rajeev Raghuvanshi, Vivekananda Kalaiselvan, Shatrunjay Shukla, V Hariharan, B Naveen Gowda","doi":"10.4103/ijp.ijp_818_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Materiovigilance is a method for tracking, documenting, and analyzing the causal factors of adverse outcomes or complications associated with the use of medical devices. In addition, it recommends that the Indian regulatory authority takes necessary steps with the aim of enhancing patient safety. The present study was taken up as there are hardly any studies available in the public domain on adverse events due to radiotherapy.</p><p><strong>Objective: </strong>The objective of the study is to analyze the pattern of adverse events due to medical devices used in the department of radiation oncology.</p><p><strong>Methods: </strong>It was a cross-sectional study carried out from June to September, 2022. The patients who were treated with the medical devices in radiation oncology at Victoria Hospital affiliated with Bangalore Medical College and Research Institute, Bengaluru, were included. The medical device used on the patients causes adverse events. The data were collected from the patient's health records available in the department of radiotherapy.</p><p><strong>Results: </strong>Total 40 adverse events collected as per inclusion and exclusion criteria were analyzed. All the adverse events associated with medical devices were filled in the medical device adverse event reporting form and submitted to materiovigilance program, which also included the causality assessment. All the adverse events were caused due to external beam radiotherapy/teletherapy device. Dermatitis was the most common adverse event found in the reported cases (n = 20, 50%).</p><p><strong>Conclusion: </strong>Materiovigilance program is in budding stage. It was observed that the adverse events in patients were due to medical devices used in radiation oncology. Medical devices with skin-sparing effect (radiation is converged onto tumor) should be promoted and more research and engineering are required in designing of advanced medical devices for the treatment of cancer across the globe.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10501536/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/ijp.ijp_818_22","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Materiovigilance is a method for tracking, documenting, and analyzing the causal factors of adverse outcomes or complications associated with the use of medical devices. In addition, it recommends that the Indian regulatory authority takes necessary steps with the aim of enhancing patient safety. The present study was taken up as there are hardly any studies available in the public domain on adverse events due to radiotherapy.
Objective: The objective of the study is to analyze the pattern of adverse events due to medical devices used in the department of radiation oncology.
Methods: It was a cross-sectional study carried out from June to September, 2022. The patients who were treated with the medical devices in radiation oncology at Victoria Hospital affiliated with Bangalore Medical College and Research Institute, Bengaluru, were included. The medical device used on the patients causes adverse events. The data were collected from the patient's health records available in the department of radiotherapy.
Results: Total 40 adverse events collected as per inclusion and exclusion criteria were analyzed. All the adverse events associated with medical devices were filled in the medical device adverse event reporting form and submitted to materiovigilance program, which also included the causality assessment. All the adverse events were caused due to external beam radiotherapy/teletherapy device. Dermatitis was the most common adverse event found in the reported cases (n = 20, 50%).
Conclusion: Materiovigilance program is in budding stage. It was observed that the adverse events in patients were due to medical devices used in radiation oncology. Medical devices with skin-sparing effect (radiation is converged onto tumor) should be promoted and more research and engineering are required in designing of advanced medical devices for the treatment of cancer across the globe.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.